BABTTOPMOUNTEXITSIGN
Our BAB (T) is a heavy duty, vandal resistant, Ligature Resistant Top Mount LED exit sign designed for high-performance and long-life.
Cross-References
26 equivalents across 10 brands
Compare top 3 →- spec →
EXIT/EM/CHICAGO features energy-efficient, long-lasting LEDs and two 5.3-watt Chicago-approved adjustable lamp heads.
- category
- subcategory
- environment
- spec →
The LHX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Back Mount
- category
- subcategory
- environment
- spec →
LED exit sign with battery backup for illumination during power loss. Luminaire is powered by LED sources for maximum life without maintenance. Ideal for egress lighting where splashing, non-corrosive liquids and dripping may occur. BODY 13" Width X 8-7/8" Height X 2-1/2" Depth Extruded aluminum housing and acrylic panel FACE Impact resistant polycarbonate white face plate with flame retardant and internal gasket for wet location rating. Optional dual face plate included. Fully illuminated 6" letters with 3/4" stroke and field selectable directional chevrons included. MOUNTING Mounting hardware included for ceiling, wall or side mount applications. Listed for installations indoor, outdoor or wet locations. ELECTRICAL Voltage: 120/277VAC 60Hz input Wattage: 2.2W Battery: 3.6V Replaceable 400mAh NiCad battery Recharge Time: 24 hours Operating Temperature: Standard: 0°C to 50°C Cold Weather Option: -25°C to 50°C EMERGENCY CIRCUIT During loss of power, NiCad battery will operate LED exit sign for 90 minutes. Battery requires 24 hours to recharge when power is restored. LABELS AND LISTINGS · UL 924 Listed for Wet Locations · NFPA 70 & NFPA 101 Life Safety Code · California Energy Commission (CEC) Compliant · Title 20 Compliant
- category
- subcategory
- environment
Single/double face configurable with supplied faceplate. 120V/277V. Sturdy ABS plastic housing. Side, top or back mounting. cUL or ETL listed.
- category
- subcategory
- environment
- spec →
QMLED Emergency Exit Sign - Magellan QM LED Exit-Unit Combo
- category
- subcategory
- environment
- spec →
This TCL Series ENTER | EXIT (120-277VAC) outdoor, blank-out sign is designed with super bright LEDs and a contrasting face; we guarantee it's readable in direct sunlight. The sign message is formed by visible LEDs on a black sign face and is designed to illuminate the message(s) when turned on and blank out or extinguish the message when off.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. It has a corrosion resistant, all-weather cabinet and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed for wet locations.
- category
- subcategory
- environment
- spec →
EXIT/EM/LED features high-performance reflectors, plastic lensing, and ultra-bright white LEDs to provide optimal light distribution for emergency situations.
- category
- subcategory
- environment
- spec →
ECC This product series has been discontinued.
- category
- subcategory
- environment
- spec →
A compact exit sign with dual color LEDs, allows end user to change the color from Red to Green in the field. The exit sign includes a maintenance-free NiCad battery to power the fixture during power loss for 90 minutes on a full charge. LED light sources require no maintenance for 25 years–saving greatly on maintenance and upkeep costs. LED exits are ideal for commercial and industrial standard non-emergency applications where low maintenance and operating costs are a must. LED Source: Internal switch changes the color of LEDs from Green to Red Colored Filters: Green and Red Filters are included with each sign Face: Double Face and Blank Face included Mounting: Wall, Side, or Ceiling Mounted. Mounting hardware and canopy included Input Voltage: 120V/277V input Battery: 3.6V 300mAh NiCad (nickel-cadmium) Testing: The manual test switch and indicator light are located on the bottom of the sign Accessories: NEG-60 (Wet Location Enclosure for Wall Mounting only) Listings: UL Listed for Damp Locations NFPA Certified to the energy efficiency standards of California Title 20
- category
- subcategory
- environment
Polycarbonate weather proof clear shield for LED Exit Signs UL Listed for wet location
- category
- subcategory
- environment
- spec →
Ideal for wet location areas requiring exit signs for AC only or battery back-up power that are subject to saturation with non-mechanically delivered water. Contemporary designed polycarbonate
- category
- subcategory
- environment
- spec →
This TCL Series EXIT w/ Arrow (120-277VAC) outdoor, blank-out sign is designed with super bright LEDs and a contrasting face; we guarantee it's readable in direct sunlight. The sign message is formed by visible LEDs on a black sign face and is designed to illuminate the message(s) when turned on and blank out or extinguish the message when off.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. The cabinet is constructed of corrosion-resistant, extruded aluminum and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed for wet locations.
- category
- subcategory
- environment
- spec →
Featuring LED exit and LED lightpipe emergency lighting in one self-contained, compact design.
- category
- subcategory
- environment
- spec →
LLXC This product webpage has been discontinued.
- category
- subcategory
- environment
- spec →
LED Exit sign with dual emergency fixtures feature Ball and Socket LED lights for full adjustability. The exit sign is powered by LED source for maximum life without maintenance; Expected life 100,000 hours. In the event of power loss, both sign and heads will operate for a minimum of 90 minutes. FEATURES • Fully adjustable 2.8 watt high-intensity LED head • Universal mounting - Wall or ceiling • UL listed and meets or exceeds UL924, NEC, OSHA and NFPA 101 Life Safety Code requirements • Injection molded high impact and scratch resistant corrosion-proof and UL94 5V-0 flame retardant housing • Push-To-Test switch • Maintenace free NiCad battery • 120V or 277V AC input • Field selectable Chevrons • 6" High and 3/4" stroke letters • External LED status indicator • Available in Black or White • Damp location listed • Wet location shield accessory available (NEG-60). Sold separately. Finishes: Black (B), or White (W) Battery: 4.8V Replaceable 1.0Ah NiCad Input Voltage: 120V or 277V AC Dimensions: Width: 1-3/4" Height: 7-1/4" Length: 11-3/4" Max Extension: 9-1/2"
- category
- subcategory
- environment
- spec →
This TCL Series EXIT w/Right Arrow outdoor, blank-out sign is designed with super bright LEDs and a contrasting face; we guarantee it's readable in direct sunlight. The sign message is formed by visible LEDs on a black sign face and is designed to illuminate the message(s) when turned on and blank out or extinguish the message when off.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. It has a corrosion resistant, all-weather cabinet and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed for wet locations.
- category
- subcategory
- environment
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →