LithoniaExit Signs

LHX-NY-EXIT-COMBO

The LHX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Back Mount

voltage: 120V/277Vsubcategory: led_exit_signfamily: LHX-NY Exit Combo - Indura® Die-formed Steel LED Exit-Unit Combo, New York City Approvedcct: 2700cri: 100wattage spec: 36housing material: steel

Cross-References

Top equivalents — 12 across 12 brands

Compare top 3
  • H.E. WilliamsEXIT-EM-CHICAGOstrong

    EXIT/EM/CHICAGO features energy-efficient, long-lasting LEDs and two 5.3-watt Chicago-approved adjustable lamp heads.

    • category
    • subcategory
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 120V/277VUNV
    • wattage: 36W10W
    spec →
  • IsoliteCLPstrong

    The CLP Chicago Approved LED Exit Sign utilizes energy-efficient white LEDs. The sign's housing unit is made of 20 gauge steel and allows for universal mounting.

    • category
    • subcategory
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 120V/277VUNV
    spec →
  • Nora LightingNX617LEDstrong

    LED exit sign with battery backup for illumination during power loss. Luminaire is powered by LED sources for maximum life without maintenance. Ideal for egress lighting where splashing, non-corrosive liquids and dripping may occur. BODY 13" Width X 8-7/8" Height X 2-1/2" Depth Extruded aluminum housing and acrylic panel FACE Impact resistant polycarbonate white face plate with flame retardant and internal gasket for wet location rating. Optional dual face plate included. Fully illuminated 6" letters with 3/4" stroke and field selectable directional chevrons included. MOUNTING Mounting hardware included for ceiling, wall or side mount applications. Listed for installations indoor, outdoor or wet locations. ELECTRICAL Voltage: 120/277VAC 60Hz input Wattage: 2.2W Battery: 3.6V Replaceable 400mAh NiCad battery Recharge Time: 24 hours Operating Temperature: Standard: 0°C to 50°C Cold Weather Option: -25°C to 50°C EMERGENCY CIRCUIT During loss of power, NiCad battery will operate LED exit sign for 90 minutes. Battery requires 24 hours to recharge when power is restored. LABELS AND LISTINGS · UL 924 Listed for Wet Locations · NFPA 70 & NFPA 101 Life Safety Code · California Energy Commission (CEC) Compliant · Title 20 Compliant

    • category
    • subcategory
    • environment
    • voltage
    • spec delta
    • wattage: 36W2.2W
    spec →
  • ChlorideENYSXSstrong

    The NYC Approved SX Series features rugged construction. Long life LED's provide excellent illumination.

    • category
    • subcategory
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 120V/277VUNV
    • wattage: 36W5W
    spec →
  • ExitronixCHIXstrong

    Chicago Offering · Chicago Offering

    • category
    • subcategory
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 120V/277V277V
    • wattage: 36W6.8W
    spec →
  • ELCO LightingEDGLITstrong

    Single clear acrylic face or Double mirrored acrylic faced LED Exit Signs Green or Red letters and arrows 120V/277V with 90 min. emergency battery backup 24 hrs rechargeable after been discharged Test switch and charge rate indicator Wall or ceiling mount cUL listed CA Title 20 Certified

    • category
    • subcategory
    • environment
    • voltage
    spec →
  • Advantage Environmental LightingX16WLWETLOCATIONLEDEXITSIGNpartial

    ILLUMINATION • Ultra-bright, energy efficient, long-life Red or Green LED. ELECTRICAL • Dual 120/277 voltage. • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing. • 4.8V long-life, maintenance-free, rechargeable NiCd battery. • Internal solid-state transfer switch automatically connects the internal battery to LED board

    • category
    • subcategory
    • environment
    spec →
  • ConTech Lighting | LevitonEXREMpartial

    Compact LED Exit Sign with Battery Back-up. Light Source : LED; Listings : Damp Location; Mounting : Wall,Ceiling; Product Type : Exits

    • category
    • subcategory
    • environment
    • voltage
    • spec delta
    • voltage: 120V/277VUNV
    • wattage: 36W2W
    spec →
  • This TCL Series ENTER | EXIT (120-277VAC) outdoor, blank-out sign is designed with super bright LEDs and a contrasting face; we guarantee it's readable in direct sunlight. The sign message is formed by visible LEDs on a black sign face and is designed to illuminate the message(s) when turned on and blank out or extinguish the message when off.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. It has a corrosion resistant, all-weather cabinet and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed for wet locations.

    • category
    • subcategory
    • environment
    • voltage
    • spec delta
    • voltage: 120V/277V120-277VAC
    spec →
  • LiteLumeLL-RMLEDCXTEUpartial

    Running Man All LED Exit Sign & Emergency Combo Long lasting, efficient ultra bright white LED lamp heads.1 watt (8 LEDs x 0.125W) per head. High performance chrome-plated metallized reflector and plastic lens for optimal light distribution. Adjustable LED lamp heads provides optimal center-to center spacing. Optional high-lumen heads are available for increased center-to-center spacing. Ultra bright, energy efficient, long-lasting white LED provides even, fully illuminated panel.

    • category
    • environment
    • voltage
    • CCT
    • spec delta
    • voltage: 120V/277V120V
    • wattage: 36W5W
    spec →
  • Sure-LitesLPXW Seriespartial

    The LPXW series provides a UL924 compliant solution for outdoor exit requirements. The fixture is wet location listed with a temperature rating of (- 20°C to 50°C ). The UV stabilized polycarbonate housing is available in white, grey or black with red or green Exit letters. Labor savings self-diagnostics that perform required monthly and yearly testing are standard for the self-powered exits.

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 36W3.4W
    spec →
  • Legion LightingEXIT SIGN - SERIES EXHLWLpartial

    HAZARDOUS LOCATION POLYCARBONATE BUY AMERICA OPTION Red or green letters. Single or double face available. Grey housing color. Field selectable knockout chevron directional indicators. Options include self diagnostics and tamperproof hardware. IP66. Rated for Class 1, Division 2, Groups A, B, C and D.

    • category
    • environment
    • voltage
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Lithonia

Full directory →

60 rep agencies carry the Acuity Brands line across 51 states. Pick your state.

+41 more states in the full directory →

Line cards are directional — confirm coverage with the agency before routing a spec.