NX617LED
LED exit sign with battery backup for illumination during power loss. Luminaire is powered by LED sources for maximum life without maintenance. Ideal for egress lighting where splashing, non-corrosive liquids and dripping may occur. BODY 13" Width X 8-7/8" Height X 2-1/2" Depth Extruded aluminum housing and acrylic panel FACE Impact resistant polycarbonate white face plate with flame retardant and internal gasket for wet location rating. Optional dual face plate included. Fully illuminated 6" letters with 3/4" stroke and field selectable directional chevrons included. MOUNTING Mounting hardware included for ceiling, wall or side mount applications. Listed for installations indoor, outdoor or wet locations. ELECTRICAL Voltage: 120/277VAC 60Hz input Wattage: 2.2W Battery: 3.6V Replaceable 400mAh NiCad battery Recharge Time: 24 hours Operating Temperature: Standard: 0°C to 50°C Cold Weather Option: -25°C to 50°C EMERGENCY CIRCUIT During loss of power, NiCad battery will operate LED exit sign for 90 minutes. Battery requires 24 hours to recharge when power is restored. LABELS AND LISTINGS · UL 924 Listed for Wet Locations · NFPA 70 & NFPA 101 Life Safety Code · California Energy Commission (CEC) Compliant · Title 20 Compliant
Cross-References
Top equivalents — 12 across 12 brands
Compare top 3 →- spec →
The LHX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Back Mount
- category
- subcategory
- environment
- voltage
- spec delta
- wattage: 2.2W → 36W
- spec →
Exitronix · Exit Combo · Specification · Industrial · Outdoor Rated
- category
- subcategory
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → 277V
Single clear acrylic face or Double mirrored acrylic faced LED Exit Signs Green or Red letters and arrows 120V/277V with 90 min. emergency battery backup 24 hrs rechargeable after been discharged Test switch and charge rate indicator Wall or ceiling mount cUL listed CA Title 20 Certified
- category
- subcategory
- environment
- voltage
- spec →
EXIT/EM/CHICAGO features energy-efficient, long-lasting LEDs and two 5.3-watt Chicago-approved adjustable lamp heads.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V/277V → UNV
- wattage: 2.2W → 10W
- spec →
ILLUMINATION • Ultra-bright, energy efficient, long-life Red or Green LED. ELECTRICAL • Dual 120/277 voltage. • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing. • 4.8V long-life, maintenance-free, rechargeable NiCd battery. • Internal solid-state transfer switch automatically connects the internal battery to LED board
- category
- subcategory
- environment
- spec →
QMLED Emergency Exit Sign - Magellan QM LED Exit-Unit Combo
- category
- subcategory
- environment
- spec →
This TCL Series ENTER | EXIT (120-277VAC) outdoor, blank-out sign is designed with super bright LEDs and a contrasting face; we guarantee it's readable in direct sunlight. The sign message is formed by visible LEDs on a black sign face and is designed to illuminate the message(s) when turned on and blank out or extinguish the message when off.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. It has a corrosion resistant, all-weather cabinet and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed for wet locations.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V/277V → 120-277VAC
- spec →
Adjustable long lasting, efficient ultra bright white LED lamp heads. One, 0.5W white LED per lamp head. Unique all inclusive lamp, reflector and lens assembly. Long-lasting, energy efficient Red or Green LED EXIT sign illumination.
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → UNV
- spec →
Low-Profile wet location Exit and Emergency combo unit, 2.5" deep. Available in white, black and grey. Stocked in selectable Red/Green for convenience. Long lasting, efficient, ultra bright white LED lamp heads. 1.0W (1 LEDs x 1.0 watt) per head. Adjustable LED lamp heads provide up to 18-ft center-to center spacing with 3-ft path of egress at 7.5-ft mounting height.
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → UNV
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →
Local Reps
Who reps Nora Lighting
Full directory →3 rep agencies carry the Nora Lighting line across 4 states. Pick your state.
Iowa IA1 agency
Statewide
Nebraska NE1 agency
Omaha
Nevada NV1 agency
Las Vegas
Wisconsin WI1 agency
- ERI / illuminateCurrent
Statewide
Line cards are directional — confirm coverage with the agency before routing a spec.