X402 LED AC-ONLY, AC/DC LED Exit Sign
Heavy-duty LED exit sign designed for Class I, Division 1 & 2, Groups C and D. Class II, Division 1 & 2, Groups E, F and G, Class III locations. The EXP Family includes combination units, battery units, and remote heads available in many configurations to suit a range of industrial applications.
Cross-References
Top equivalents — 12 across 12 brands
Compare top 3 →- spec →
ILLUMINATION • Adjustable long lasting, efficient ultra bright white LED lamp heads. • One, 0.5W white LED per lamp head. • Unique all inclusive lamp, reflector and lens assembly. • Long-lasting, energy efficient Red or Green LED EXIT sign illumination. ELECTRICAL • Dual 120V/277 voltage standard. Optional dual 120V/230V available.
- category
- subcategory
- environment
- voltage
- spec delta
- wattage: 100W → 1W
- spec →
The New York City Approved LED Exit Sign, Chloride 40 Line is constructed of die cast aluminum. This universal exit sign contains a Self Diagnostic/Self -Test circuitry as a standard feature on self powered battery versions.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → UNV
- wattage: 100W → 3.5W
- spec →
The New York City Approved LED Exit Sign, Chloride 40 Line is constructed of die cast aluminum. This universal exit sign contains a Self Diagnostic/Self -Test circuitry as a standard feature on self powered battery versions.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → UNV
- wattage: 100W → 3.5W
- spec →
This SBL Series NOT AN EXIT indoor, blankout, LED backlit sign is designed with a matrix of energy efficient LEDs illuminating a block-style message. The sign features blankout technology that only displays the sign message when illuminated.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. The cabinet is constructed of corrosion-resistant, extruded aluminum and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → 120-277VAC
- spec →
EXIT/EM/CHICAGO features energy-efficient, long-lasting LEDs and two 5.3-watt Chicago-approved adjustable lamp heads.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → UNV
- wattage: 100W → 10W
- spec →
The LHX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Back Mount
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → 120V/277V
- wattage: 100W → 36W
- spec →
LED exit sign with battery backup for illumination during power loss. Luminaire is powered by LED sources for maximum life without maintenance. Ideal for egress lighting where splashing, non-corrosive liquids and dripping may occur. BODY 13" Width X 8-7/8" Height X 2-1/2" Depth Extruded aluminum housing and acrylic panel FACE Impact resistant polycarbonate white face plate with flame retardant and internal gasket for wet location rating. Optional dual face plate included. Fully illuminated 6" letters with 3/4" stroke and field selectable directional chevrons included. MOUNTING Mounting hardware included for ceiling, wall or side mount applications. Listed for installations indoor, outdoor or wet locations. ELECTRICAL Voltage: 120/277VAC 60Hz input Wattage: 2.2W Battery: 3.6V Replaceable 400mAh NiCad battery Recharge Time: 24 hours Operating Temperature: Standard: 0°C to 50°C Cold Weather Option: -25°C to 50°C EMERGENCY CIRCUIT During loss of power, NiCad battery will operate LED exit sign for 90 minutes. Battery requires 24 hours to recharge when power is restored. LABELS AND LISTINGS · UL 924 Listed for Wet Locations · NFPA 70 & NFPA 101 Life Safety Code · California Energy Commission (CEC) Compliant · Title 20 Compliant
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → 120V/277V
- wattage: 100W → 2.2W
Single/double face configurable with supplied faceplate. 120V/277V. Sturdy ABS plastic housing. Side, top or back mounting. cUL or ETL listed.
- category
- subcategory
- environment
- voltage
- spec delta
- voltage: 120V → 120V/277V
- spec →
QMLED Emergency Exit Sign - Magellan QM LED Exit-Unit Combo
- category
- subcategory
- environment
- spec delta
- wattage: 100W → 1.5W
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →
Local Reps
Who reps Lightalarms
Full directory →36 rep agencies carry the Lightalarms line across 49 states. Pick your state.
Alabama AL2 agencies
Mobile
- Lighting PartnershipCurrent
Birmingham
Arizona AZ1 agency
Statewide
Arkansas AR1 agency
- Curtis Stout, Inc.Current
Statewide
California CA3 agencies
- LINX Lighting + ControlsSignify (Philips)
Los Angeles · San Diego · Ventura
Fresno
Sacramento · San Francisco
Colorado CO1 agency
- Fisher Lighting And ControlsCurrent
Statewide
Connecticut CT1 agency
Statewide
Delaware DE1 agency
Statewide
District of Columbia DC1 agency
- Commercial Lighting SalesCurrent
Statewide
Florida FL2 agencies
Panhandle
- FRM Lighting & ControlsCurrent
Fort Myers · Jacksonville · Miami · Orlando · Tampa
Georgia GA1 agency
- Lighting Associates, Inc.Acuity Brands
Atlanta · Savannah
+39 more states in the full directory →
Line cards are directional — confirm coverage with the agency before routing a spec.