GreengateEmergency Units

CEPC-2

Greengate allows control of emergency lighting by any Greengate lighting control panel or OCC sensor

compliance: UL 924family: CEPC-2dimming: 0-10Vvoltage: 120V

Cross-References

Top equivalents — 12 across 12 brands

Compare top 3
  • LiteLumeLL-CAEMpartial

    LED Chicago Approved Steel Emergency Unit Two, 6V adjustable white LED lamp heads in metal housing and PC lens provide optimal light distribution. 3.3W (3 LEDs x 1.1W) per head with a light output of 335 lumens.

    • category
    • environment
    • voltage
    spec →
  • IsoliteODLMpartial

    The ODLM has very low profile extruded aluminum housing and mount bracket blend seamlessly with structural metal frames.

    • category
    • environment
    • voltage
    spec →
  • Myers EPS offers a line of micro inverters for emergency lighting. The Illuminator Series LVU systems fits many compact applications.

    • category
    • environment
    • voltage
    • dimming
    spec →
  • LithoniaELT-EMERGENCY-UNITpartial

    Provides a minimum 90 minutes of illumination for the rated wattage upon loss of AC power. Designed for general/light industrial environments requiring a steel housing. Glass sealed-beam style

    • category
    • environment
    • voltage
    spec →
  • nLightDCHUBpartial

    The DCHUB is a required component of the DC2DC Architecture. Distributes Class 2 low voltage DC power to DC-powered LED luminaires, including support for either all emergency lighting or all

    • category
    • environment
    • voltage
    spec →
  • ConTech Lighting | LevitonR4NCpartial

    Universal New Construction Downlight. Product Category : 4-Inch Downlight; Product Type : Downlight; Product Shape : Round; Housing : New Construction; Environment : Damp Location; Compliance : ENERGY STAR® Certified,Certified to UL924 Standard for Emergency Lighting; Correlated Color Temperature : 2700K,3000K,3500K,4000K; Color Rendering Index : 80-89,90-100

    • category
    • environment
    • voltage
    • dimming
    spec →
  • Nora LightingNSEM6WDpartial

    A surface mount enclosure with an emergency LED driver for use with 6" ELO and ELO+ luminaires. It adds 1-1/2" height to the luminaire and matches the finish. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Compatible with 6" ELO & ELO+ Matching decorative enclosure also available Listed for field installation - UL 924 and CSA C2.22 No 141 Includes integral test switch ELECTRICAL Input Voltage: 120VAC, 50/60Hz Output Voltage: 123/131VDC Wattage: 3W Illumination Time: 90 minutes OPERATION When AC power fails, the driver immediately switches to the emergency mode, operating the LEDs at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency driver automatically returns to the charging mode. BATTERY Ternary lithium-ion battery requires 24 hours to recharge. COMPATIBLE LUMINAIRES NELO-6RTWMPW: 6" ELO with Selectable CCT, 1050lm / 15W, 90+ CRI (use NELO-6RW to match finish) NELOCAC-6RP: 6" ELO+ with Dedicated CCT, 700lm / 12W, 90+ CRI MATCHING DECORATIVE ENCLOSURE NSEM-6ND: Decorative Enclosure without Emergency Driver

    • category
    • environment
    • voltage
    spec →
  • ELCO LightingKEM-LD7partial

    90 Min. of Emergency Light 5°C to 50°C operating temperature. Input: 120V, 50-60Hz Output: ~110VAC (120VAC input) Output: 15W Max Compatible with EL386, EL485, EL770, EL570 series, Ply Sylo™, 4" Koto Sylo™ systems UL Listed

    • category
    • environment
    • voltage
  • Ideal for wet location areas requiring emergency lighting that are subject to saturation with non-mechanically delivered water. Contemporary designed polycarbonate housing is impact-resistant,

    • category
    • environment
    • voltage
    spec →
  • Power SentryPSBCED10-BATTERY-PACKpartial

    Versatility, peace of mind, ease of installation and use are the hallmarks of the Power Sentry emergency lighting solutions. The optional Power Sentry® PSBCED10 module enables Power Sentry PS1030 and

    • category
    • environment
    • voltage
    spec →
  • This 8 watt nickel-cadmium (NiCd) battery backup system is designed for use with the Edge Round 8'' flush mount (sold separately). It provides 90 minutes of power to the Edge Round 8'' flush mount to allow lighting for emergency egress or continuation of key operations during a loss of power.

    • category
    • environment
    • voltage
    spec →
  • DMX Lighting Control Panel with Remote Control Breakers Looking for an efficient lighting control load center? The LCLC series of DMX controlled Load Centers uses motorized circuit breakers to offer a labor-saving one-panel alternative to DMX relay panels. Instead of a bulky setup with separate panels for different audio, visual, and lighting systems, a high quality LynTec lighting power control panel can solve your space issues. The economical Load Center panels require the least wall space for tight locations and are perfect if you are trying to save on valuable room. These compact and sleek panels are available in 26 and 41 circuit sizes od 3 phase, 4 wire 208Y/120Vac. Many small theaters, intimate restaurants, conference rooms, and other locations have found these incredibly useful. A Lighting Control Load Center is a traditional residential panel and consequently best suited for smaller circuit breaker counts or for applications with limited wall space. For a bigger arena, auditorium, or other venue, one of LynTec’s many other state of the art products would be more appropriate. The LCLC is more economical than the bigger panelboards, and is a great value for all of the features offered! Here are just a few of the high end features of this lighting power control: DMX 512 control standard in all panels, a simple jumper system sets your addressing Control circuits individually or in zoned group Simplest control set-up and operation in the industry No on-site commissioning or factory start-up required Emergency auto-on feature for egress lighting standard (ETL listed UL 924) Saves Space Saves redundant installation and hardware costs! Energy efficient – NO holding current or heat sinks required to maintain state – Runs cool, lasts long! Many of these features make sure that your Lighting Control Load Center is convenient and easy to use, from the limited space it take up to the ability to have zone control. Save time, money, and space with the LCLC.

    • category
    • environment
    • voltage
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Greengate

Full directory →

43 rep agencies carry the Cooper Lighting Solutions line across 51 states. Pick your state.

+41 more states in the full directory →

Line cards are directional — confirm coverage with the agency before routing a spec.