ExitronixEmergency Units

RM2

General Purpose · Emergency Lighting · New York City Emergency Lighting · New York City Emergency Lighting · New York City Offering

family: RM2 Series Recessed Emergency Lighting Unitwattage spec: 1voltage: 277Vhousing material: steel

Cross-References

Top equivalents — 12 across 12 brands

Compare top 3
  • ParaflexPFX-5541partial

    The PARAFLEX PFX‑5541 is a decorative LED emergency lighting unit with universal 120–277V input, four 1.0‑watt LED heads, and a 90‑minute minimum runtime. It features a maintenance‑free NiMH battery, 5VA flame‑retardant thermoplastic housing, and is UL listed for damp locations. An optional self‑diagnostic feature is available.

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 277VUNV
    spec →
  • LiteLumeLL-LEDR2partial

    Five year warranty on all electronics and housing. Battery prorated for five years.

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 277VUNV
    spec →
  • LuminosoLE WPL 2 F W Npartial

    Injection-molded thermoplastic ABS housing

    • category
    • environment
    • voltage
    spec →
  • The StairLite 2 is designed to satisfy all stairwell lighting requirements in one easy-to-install package. The StairLite 2 is a surface-mounted, two-lamp fluorescent lighting fixture that incorporates an integrally mounted ultrasonic motion detector, a system display panel, and an optional battery backup. Either one or both lamps can be controlled by the motion sensor. Bi-level lamp operation is standard so that one lamp will remain on constantly for security and the motion detector will activate the second lamp as needed to significantly reduce the operating cost.

    • category
    • environment
    • voltage
    • housing
    • spec delta
    • wattage: 1W73W
    spec →
  • Combining the functionality of a switchpack, a sensor, and a 0-10V dimmer, this convenient wallbox device saves labor costs and reduces installation times. What's more: it meets all the latest energy codes and standards, including Title 24. This model features both ultrasonic (US) and passive infrared (PIR) sensing technologies.

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 1W277W
    spec →
  • Sure-LitesRG Seriespartial

    The RG Series is perfect for commercial or architectural applications where the aesthetics of a fully recessed unit are essential. The slim profile of the RG-1 is ideal for low ceilings and blends inconspicuously with existing recessed installations.

    • category
    • environment
    • voltage
    spec →
  • H.E. WilliamsEMER-CP-ADJ-LEDpartial

    With two adjustable LED lamp heads of the EMER/CP/ADJ/LED allows the customer the ability to orient emergency lighting to the optimal angle for any given situation. The 3.6V long-life rechargeable NiCd battery provides the unit with 90 minutes of emergency operation.

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 277VUNV
    spec →
  • IsoliteELCD-1008partial

    The ELCD Transfer Switches enable standard light fixtures to be used as emergency light sources. Fire alarm interface and dimming control interface compatible.

    • category
    • environment
    • voltage
    spec →
  • Myers EPS has more than 60 years of experience serving the growing emergency power batteries needs of customers both domestic and abroad. Contact us today!

    • category
    • environment
    • voltage
  • Dual-LiteELSS-EMERGENCY-LIGHTINGpartial

    Ease of Installation and Maintenance

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 1W100W
  • TivoliECLIPSEWALLpartial

    The Eclipse Wall is an indirect wall safety lighting system. Its ideal applications are interior walkways, egress, walkways, and stairs.

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 1W800W
    spec →
  • Nora LightingNEPK07LEDUNVpartial

    Emergency LED driver for use with new or existing LED luminaires. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Listed for field installation - UL 924 and CSA C2.22 No 141 Class 2 output - UL 1310 certified, CSA 22.2 No 223-M91 Controlled power for predictable discharge 10 - 60VDC for wide range of LED loads Universal input (120 through 277VAC, 50/60Hz) Includes wall plate with test switch Certified to the energy efficiency standards of California Title 20 Accessory: NEPKA-07LEDFPTS: Replacement Remote Test Switch

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 1W7W
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →