TCL
Contemporary LED emergency light design for commercial interiors.
Cross-References
Top equivalents — 12 across 10 brands
Compare top 3 →Highest-output ELM Quantum dual-head emergency unit at 1100 lumens. For large open areas requiring maximum coverage.
- category
- voltage
- duration
- spec delta
- voltage: 120/277 VAC → 120-277V MVOLT
The AtLite ATLEL series provides a NEMA 4X and UL924 code compliant emergency lighting solution for extreme commercial and industrial environments. The rugged die cast aluminum housing and UV stabilized polycarbonate lens are designed to withstand harsh environmental conditions. The fixture is wet location listed with a temperature rating of -30° to 50°C (-22° to 122°F), is IP66 listed and has a Hazardous location class 1 division 2 option. Two 300 lumen LED heads provide up to 58 feet of emergency egress coverage. Labor saving self diagnostics with a photocell testing capability are standard and perform required monthly and yearly testing. Tamper resistant screws are included to make the fixture vandal resistant.
- category
- voltage
- lumens
- spec delta
- voltage: 120/277 VAC → 277V/UNV
- wattage: 2W → 5W
- spec →
The SELMTG60R5SD is an Architectural grade, recessed, T-Grid mounted emergency light. The 300 lumen LED source will cover up to 60 feet resulting in less total fixtures required. Also, the adjustable recessed heads eliminate the traditional unsightly emergency fixture look. This product is UL924 listed and meets both City of Chicago and NYC construction requirements.
- category
- voltage
- lumens
- spec delta
- voltage: 120/277 VAC → UNV
- wattage: 2W → 5W
- spec →
This low profile fixture offers the lowest profile of all Nora Emergency fixtures. The light sources are held within the body of the fixture, with both beveled side panels constructed of clear polycarbonate. These features make the emergency light small enough for virtually any application, and eliminate the necessity of aiming and locking lamp heads. BODY 11-7/8" Width X 5-1/8" Height X 2-3/4" Depth Injection-molded housing with access for ceiling or wall power supply. FACE Injection molded face with two clear polycarbonate covers on beveled surfaces. MOUNTING Wall or ceiling Mounting hardware included Electrical 120/277V input Automatic solid state switching and charging Automatic reset Battery Replaceable 3.6V, 1000mAh NiCad battery for backup operation during power loss 90 minute emergency operation on fully charged battery Testing High-charge/ready operation indicator light Test button Circuitry Protection Short circuit protection Listings UL 924 NFPA 70 & NFPA 101 Suitable for damp location
- category
- voltage
- wattage
- spec delta
- lumens: 300 → 110
- spec →
Mini Emergency Light with two 2W fully adjustable glare-free square shape light heads for emergency light. Injection-molded thermoplastic ABS housing Innovative snap-together design allows for fast and easy installation. 250 lm (total) 3.6V, 1.5Ah battery pack for 90 minutes of emergency operation. LED Driver: 120V/277V AC, dual voltage operation integrated with LED bulb. cUL listed for damp location.
- category
- voltage
- wattage
- spec →
The LightLEEDer Emergency UL 924 bypass relay control panel will force relay's ON during a normal power outage. This panel has all the same features and functions as a standard LightLEEDer lighting controller, allowing normal control of relays with emergency bypass during a normal power failure event. Relays can be all EM or a combination of normal and EM. Each output has a jumper for selecting Force On, Force Off or No change, this allows for emergency on, load shedding off, or no control selection for each relay. Provided With Phase monitoring module and high voltage dividers. This LightLEEDer Emergency lighting panel is easy to install, no external devices or complicated wiring configurations needed, reducing material and installation costs.
- category
- voltage
- spec delta
- wattage: 2W → 1W
- spec →
The EB5 fluorescent emergency ballast works in conjunction with the AC ballast to covert new or existing fluorescent fixtures into emergency lighting. When AC power fails, the EB5 immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.
- category
- voltage
- lumens
- spec delta
- voltage: 120/277 VAC → UNV
- wattage: 2W → 17-40W
Contractor Select EU2C dual LED lamp head emergency light - most popular and readily available EU2C configuration.
- category
- voltage
- duration
- spec →
Sure-Lites SELMTG60R5SD is an Architectural grade, recessed, T-Grid mounted emergency light.
- category
- voltage
- lumens
- spec delta
- voltage: 120/277 VAC → UNV
- wattage: 2W → 5W
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →
Local Reps
Who reps Evenlite
Full directory →52 rep agencies carry the Evenlite line across 51 states. Pick your state.
Alabama AL1 agency
- Lighting PartnershipCurrent
Birmingham · Mobile
Alaska AK1 agency
- Alaska Architectural LightingAcuity Brands
Statewide
Arizona AZ1 agency
- R.C. LurieAcuity Brands
Statewide
Arkansas AR1 agency
Statewide
California CA3 agencies
- ALRSignify (Philips)
Fresno · Sacramento · San Francisco
- OCS Lighting & ControlCurrent
San Diego
- PLP SoCalCurrent
Los Angeles · Ventura
Colorado CO1 agency
- The Lighting AgencyAcuity Brands
Statewide
Connecticut CT1 agency
- illuminateCurrent
Statewide
Delaware DE1 agency
Statewide
District of Columbia DC1 agency
- Chesapeake LightingCooper (Eaton)
Statewide
Florida FL5 agencies
- Power & Lighting SystemsAcuity Brands
Miami
- Lighting Partners of Central FloridaCooper (Eaton)
Orlando
- Tampa Bay LightingCooper (Eaton)
Tampa
Jacksonville
- Karl Volk & Co.
Panhandle
+41 more states in the full directory →
Line cards are directional — confirm coverage with the agency before routing a spec.