EvenliteEmergency Units

SNY2-B

NYC-approved 20 ga steel emergency light with two 9.6V LED heads, black finish.

subcategory: steel_nyc_approvedfamily: Tufflite SNYvoltage: 120/277 VACbattery: 9.6V NiCdduration minutes: 90housing color: Blackwattage spec: 1.5housing material: steel

Cross-References

Top equivalents — 12 across 9 brands

Compare top 3
  • Sage EmHAWpartialSUGGESTED

    Premium Lensed Strip Light · Luminaires Series HAW

    • category
    • spec delta
    spec →
  • LithoniaELM6Lpartial

    Highest-output ELM Quantum dual-head emergency unit at 1100 lumens. For large open areas requiring maximum coverage.

    • category
    • voltage
    • duration
    • spec delta
    • voltage: 120/277 VAC120-277V MVOLT
  • Sure-LitesSELWweak

    The Sure-Lites Wet location Emergency Light (SELW) is designed to reduce total egress system cost and maintenance in a wet location environment as well as improve system reliability. Key features include long life LED’s, proprietary rotatable accuLED optics, a nickel cadmium battery. The SELW is UL924 wet location code compliant listed with a standard 0°C to 40°C temperature rating. The SELW’s easy hang feature reduces installation time and cost.

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VAC277V
    spec →
  • IsoliteE3MINIweak

    The E3MINI Pure Sine Wave Mini Inverter provides a field-selectable 120 or 277 VAC input/output. It is UL 924 and CSA 22.2 approved.

    • category
    • voltage
    • spec delta
    • wattage: 1.5W250W
    spec →
  • Nora LightingNEPK23LEDUNVweak

    Emergency LED driver for use with new or existing LED luminaires. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Listed for field installation - UL 924 and CSA C2.22 No 141 Controlled power for predictable discharge Includes wall plate with test switch Input Voltage: 120-277VAC Output Voltage: 120VAC (during emergency operation) Output Wattage: 23W Compatible Luminaires: NCSC: 4" & 6" Contractor Series Can-less Downlights NCSD: 6" Contractor Series Disk Lights NCSR: 4" & 6" Contractor Series Retrofits NEFLINTW: 4" & 6" FLIN Can-less Regressed Baffle Downlights NELOSW: 4", 6" & 8" ELO Surface Mounts with Selectable Lumens & CCT NFLAT: 4" & 6" FLAT Can-less Non-Metallic Downlights NFLINA: 4" & 6" FLIN Can-less Adjustable Downlights NFRC: 4" & 6″ Fire Rated Can-less Downlights NJCB-12: 2" & 4" Iolite Can-less Driver Box NLCBC2: 4", 5" & 6" Cobalt Click Retrofits with Selectable CCT NLRS: 6" Sloped Retrofits NLOPAC-R6REGT24TW: 6" Regressed Opal Surface Mount NLOPAC2-R6509T24: 6" Opal 2 Surface Mount NLOS: 4", 6" & 7" SURF Surface Mounts NLTH: 4", 6" & 8" Theia Can-less Downlights NM1-PRDC: 1" M1+ Can-less Downlight NM2: 2" M2 Can-less Downlights NM4: 4" M4 Can-less Downlights NMC: 4" & 6" M-Curve Can-less Adjustable Downlights NMW: 2" & 4" M-Wave Can-less Adjustable Downlights NOXAC-431TW: 4" Onyx Retrofit Reflector with Selectable CCT NOXAC-432TW: 4" Onyx Retrofit Baffle with Selectable CCT NOXAC-4RGTW: 4" Onyx Adjustable Retrofit with Selectable CCT NOXAC-4RWTW: 4" Onyx Round Wall Wash Retrofit with Selectable CCT NOXAC-4SWTW: 4" Onyx Square Wall Wash Retrofit with Selectable CCT NOXAC-5631TW: 5"/6" Onyx Retrofit Reflector with Selectable CCT NOXAC-5632TW: 5"/6" Onyx Retrofit Baffle with S

    • category
    • voltage
    • spec delta
    • wattage: 1.5W9W
    spec →
  • BodineGTDweak

    Bodine Emergency Switch Bypass Devices, | Bodine

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VACUNV
    spec →
  • ELCO LightingEE80Lweak

    Mini Emergency Light with two 2W fully adjustable glare-free square shape light heads for emergency light. Injection-molded thermoplastic ABS housing Innovative snap-together design allows for fast and easy installation. 250 lm (total) 3.6V, 1.5Ah battery pack for 90 minutes of emergency operation. LED Driver: 120V/277V AC, dual voltage operation integrated with LED bulb. cUL listed for damp location.

    • category
    • voltage
  • Intelligent Lighting ControlsLLxx-EM UL924 Relay Panelweak

    The LightLEEDer Emergency UL 924 bypass relay control panel will force relay's ON during a normal power outage. This panel has all the same features and functions as a standard LightLEEDer lighting controller, allowing normal control of relays with emergency bypass during a normal power failure event. Relays can be all EM or a combination of normal and EM. Each output has a jumper for selecting Force On, Force Off or No change, this allows for emergency on, load shedding off, or no control selection for each relay. Provided With Phase monitoring module and high voltage dividers. This LightLEEDer Emergency lighting panel is easy to install, no external devices or complicated wiring configurations needed, reducing material and installation costs.

    • category
    • voltage
    spec →
  • TechlightDlgweak

    The DLG Canopy light was designed as a high performance canopy light for parking garages. The removable upper reflector allows for uplight when elimnated. It is segmented to allow the installer to direct the light specifically to the points of egress and away from a driver’s direct line of sight.

    • category
    • voltage
    • spec delta
    • wattage: 1.5W175W
    spec →
  • Sage EmREEpartialSUGGESTED

    LED Strip Light — Lumen & Kelvin Selectable. Emergency lighting with adjustable Sage Relay (Sage Relay), powered from a low-voltage central battery system.

    • category
    • spec delta
    spec →
  • LithoniaEU2C M6partial

    Contractor Select EU2C dual LED lamp head emergency light - most popular and readily available EU2C configuration.

    • category
    • voltage
    • duration
  • Sure-LitesSELW25BZweak

    Sure-Lites LED Outdoor Emergency - Wet Location

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VAC277V
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Evenlite

Full directory →

52 rep agencies carry the Evenlite line across 51 states. Pick your state.

+41 more states in the full directory →

Line cards are directional — confirm coverage with the agency before routing a spec.