Sure-LitesEmergency Units

SEL55SF

SEL55SF Unit Equipment

compliance: UL 924family: SEL55SFlumens: 520cct: 5000wattage spec: 2.2voltage: 277Vhousing material: thermoplastic

Cross-References

30 equivalents across 30 brands

Compare top 3
  • BodineBUA2WFL1exact

    Bodine Emergency Luminaires, | Bodine

    • category
    • environment
    • voltage
    • lumens
    • CCT
    • wattage
    • +1 more
    spec →
  • The Dynamo Family offers the latest technology and features. The LEDs never require replacement, the battery offers 30% longer life, and the photometric performance exceeds any other industrial emergency unit on the market. The Dynamo Family offers continuous lumen output for the full 90 minutes required by code ensuring maximum visibility when you need it most.

    • category
    • environment
    • voltage
    • lumens
    • CCT
    • housing
    • +1 more
    • wattage: 2.2W12W
  • ParaflexPFX-5543partial

    • Ultra-bright, energy efficient, long-life White LED adjustable lamp heads provide up to 30-ft center-to center spacing with 3-ft path of egress at 10-ft mounting height. • 1.5 watt (3 LEDs x 0.50 watt) per head. • Unique all-inclusive lamp, reflector and lens assembly.

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 277VUNV
    spec →
  • LuminosoLE WPL 2 F W Npartial

    Injection-molded thermoplastic ABS housing

    • category
    • environment
    • voltage
    spec →
  • IsoliteELCD-1008partial

    The ELCD Transfer Switches enable standard light fixtures to be used as emergency light sources. Fire alarm interface and dimming control interface compatible.

    • category
    • environment
    • voltage
    spec →
  • Myers EPS has more than 60 years of experience serving the growing emergency power batteries needs of customers both domestic and abroad. Contact us today!

    • category
    • environment
    • voltage
  • LithoniaELM2L-EMERGENCY-UNITpartial

    The ELM2L Series from the Lithonia Lighting® Quantum® Family is a thermoplastic, dual round head emergency unit allowing for maximized spacing between units down long hallways and open spaces. ELM2L

    • category
    • environment
    • voltage
    • CCT
    • spec delta
    • voltage: 277VUNV
    • lumens: 520220
    • wattage: 2.2W4.8W
    spec →
  • Sun Valley LightingLCN12WMpartial

    The LCN12-WM Series takes the LCN Craftsman lantern series and creates a complementary wall mount featureing a durable cast aluminum housing with clear acrylic diffusing lenses. This fixture provides uniform illumination through advanced LED technology, making it ideal for traditional walkways and building approach as well as path of egress. BABA compliant. UL listed for wet location. Optics are Dark Sky compliant with a U0 BUG rating for specific configurations.

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 277VUNV
    • cct: 5000K2700K
    spec →
  • ConTech Lighting | LevitonEL2HALEDEMpartial

    Remote Capable Dual Adjustable LED Emergency Light. Light Source : LED; Listings : Damp Location; Mounting : Ceiling,Wall; Product Type : Emergency

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 2.2W5W
    spec →
  • TivoliECLIPSEWALLpartial

    The Eclipse Wall is an indirect wall safety lighting system. Its ideal applications are interior walkways, egress, walkways, and stairs.

    • category
    • environment
    • voltage
    • spec delta
    • cct: 5000K4000K
    • wattage: 2.2W800W
    spec →
  • Nora LightingNEPK07LEDUNVpartial

    Emergency LED driver for use with new or existing LED luminaires. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Listed for field installation - UL 924 and CSA C2.22 No 141 Class 2 output - UL 1310 certified, CSA 22.2 No 223-M91 Controlled power for predictable discharge 10 - 60VDC for wide range of LED loads Universal input (120 through 277VAC, 50/60Hz) Includes wall plate with test switch Certified to the energy efficiency standards of California Title 20 Accessory: NEPKA-07LEDFPTS: Replacement Remote Test Switch

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 2.2W7W
    spec →
  • ExitronixLED-60partial

    General Purpose · Emergency Lighting

    • category
    • environment
    • voltage
    • housing
    • spec delta
    • wattage: 2.2W1W
    spec →
  • Trace-LiteLE-C6partial

    Trace-Lite · LiteLogic · Bluetooth Controls · Power Adapters / Controllers

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 2.2W5W
    spec →
  • ELCO LightingEE80Lpartial

    Mini Emergency Light with two 2W fully adjustable glare-free square shape light heads for emergency light. Injection-molded thermoplastic ABS housing Innovative snap-together design allows for fast and easy installation. 250 lm (total) 3.6V, 1.5Ah battery pack for 90 minutes of emergency operation. LED Driver: 120V/277V AC, dual voltage operation integrated with LED bulb. cUL listed for damp location.

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 277V120V/277V
  • HolophaneCZQ6L-EMERGENCY-LIGHTpartial

    The CZQ6L from Holophane® is an aesthetically pleasing emergency LED light fixture. It provides a minimum of 90 minutes of illumination with constant light output when there is a loss of power.

    • category
    • environment
    • voltage
    • CCT
    • spec delta
    • voltage: 277VUNV
    • lumens: 5201100
    • wattage: 2.2W32W
    spec →
  • TechlightEb7partial

    The EB7 fluorescent emergency ballast works in conjunction with the AC ballast to covert new or existing fluorescent fixtures into emergency lighting. When AC power fails, the EB7 immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.

    • category
    • environment
    • voltage
    • lumens
    • spec delta
    • voltage: 277VUNV
    • wattage: 2.2W17-110W
    spec →
  • This flexible fixture can be used in numerous applications as the lumens and options allow it to be used as a replacement for industrial strips, vanity lighting, stairwells, retail and hallway applications. Options include occupancy sensors, tandem wiring to permit continuous rows, emergency lighting, and CCT Selectable.

    • category
    • environment
    • voltage
    • CCT
    • spec delta
    • voltage: 277V90-305V
    spec →
  • LiteLumeLL-LEDXRweak

    LED High Output Industrial Remote Capable Thermoplastic Emergency Unit Ultra-bright, energy efficient, long-life White LED adjustable lamp heads provide up to 100-ft center-to center spacing with a 6-ft path of egress at 15-ft mounting height. 6.0 watt (12 LEDs x 0.50 watt) per head. Adjustable glare-free PAR-Type lamp heads with all inclusive lamp, reflector and lens assembly.

    • category
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 277VUNV
    • wattage: 2.2W100W
    spec →
  • The EMO2A Series features two LED fully adjustable lamp heads in a contemporary design. quick installation and premium options, in a stylish and economical package. This fixture offers quick installation and premium options in a stylish and economical package.

    • category
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 277VUNV
    spec →
  • H.E. WilliamsEMER-CP-ADJ-LEDweak

    With two adjustable LED lamp heads of the EMER/CP/ADJ/LED allows the customer the ability to orient emergency lighting to the optimal angle for any given situation. The 3.6V long-life rechargeable NiCd battery provides the unit with 90 minutes of emergency operation.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    • wattage: 2.2W1W
    spec →
  • Branch Circuit Emergency Lighting Control Transfer Switch Lighting

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    spec →
  • Brownlee Lighting1160LEDweak

    Fresh take on a traditional form factor, EMERGE is packed with upgrades and optional features such as integral Battery Backup (no extension required), integral Bi-Level Dimming control (illuminates when motion is detected, dims after set period of inactivity), traditional Occupancy control (illuminates when motion is detected, turns off after set period of inactivity), and more. USA-fabricated aluminum in your choice of finish, USA-extruded acrylic diffuser. Use this architectural sconce for any application requiring general illumination, simple energy savings and egress control, and a decorative aesthetic. Designed to be just wide enough to cover a 4x4 box, making it ideal for renovations as well.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    • lumens: 5203750
    • cct: 5000K3500K
    • wattage: 2.2W32W
    spec →
  • SPI LightingSEBRING3DOPENWINDOWweak

    The Sebring ADA compliant sconce provides path of egress lighting with sophisticated style. Color gels can add a vivid splash of color to a space and complement...

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    • cct: 5000K2700K
    spec →
  • Cree LightingST3-SIweak

    Introducing the Styllus Linear® Series that can surface or wall mounted, suspended or slot-installed for an unbroken ceiling plane.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277V347V/120V/277V
    • cct: 5000K3000/3500/4000K
    • wattage: 2.2W10W
  • Luminaire LEDAEL-WALLPACKweak

    AEL combines a unique, patented design shaped with high performance, full cut-off optics to achieve completely unobtrusive illumination of a space or path of egress. When mounted over a doorway, the

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    • cct: 5000K2700K
    spec →
  • Power SentryPS1400QD-MVOLTweak

    The PS1400QD MVOLT by IOTA® provides reliable emergency lighting in a compact design suited for low-profile troffers, downlights, and industrial luminaires. The emergency ballast includes a

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    spec →
  • Pathway ConnectivityPWEMDMX-EMERGENCY-DMX-CONTROLLERweak

    The Pathway DMeXit is a UL924 compliant controller designed to send a control signal to DMX lighting in emergencies to satisfy minimum luminance levels for egress lighting. Using a wet or dry contact

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277VUNV
    spec →
  • Intelligent Lighting ControlsLLxx-EM UL924 Relay Panelweak

    The LightLEEDer Emergency UL 924 bypass relay control panel will force relay's ON during a normal power outage. This panel has all the same features and functions as a standard LightLEEDer lighting controller, allowing normal control of relays with emergency bypass during a normal power failure event. Relays can be all EM or a combination of normal and EM. Each output has a jumper for selecting Force On, Force Off or No change, this allows for emergency on, load shedding off, or no control selection for each relay. Provided With Phase monitoring module and high voltage dividers. This LightLEEDer Emergency lighting panel is easy to install, no external devices or complicated wiring configurations needed, reducing material and installation costs.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277V120/277VAC
    • wattage: 2.2W1W
    spec →
  • The SENSORWORX Emergency Power Control device provides a simple method of converting standard light fixtures into emergency light fixures for a UL924 compliant emergency application. Designed by LVS Controls, the SWX-EPC-2 family ensures compliance with both life safety and energy codes and eliminates the wasted energy that is used when emergency lighting is kept on 24 hours a day. These devices are typically ceiling or wall mounted in a junction box with a single gang plaster ring and are usually located in the area where the emergency fixtures are installed.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277V120-277V
    • wattage: 2.2W1200-1500W
    spec →
  • Retrofit DMX Lighting Control Relay Panel Tested, complete package — low labor — mount next to circuit breaker panel to control AC power “hot” lines Reliable Panasonic latching in modules of 4 relays for easy expansion Low power consumption — no continuous relay coil current — runs cool for long life Diagnostic LEDs and internal ON -OFF test switches speed installation for testing and troubleshooting Cabinet and all components connected to high voltage are ULlisted — Electrician friendly 4, 8 or 12 circuits — 120, 240 or 277volt models available Daisy-chains for unlimited circuit count control DMX 512 control standard in all panels, a simple jumper system sets your addressing Control circuits individually or in zoned group Simplest control set-up and operation in the industry No on-site commissioning or factory start-up required Emergency auto-on feature for egress lighting standard (ETL listed UL 924) Saves Space Saves redundant installation and hardware costs! Energy efficient – NO holding current or heat sinks required to maintain state – Runs cool, lasts long!

    • category
    • environment
    • voltage
    • spec delta
    • voltage: 277V125V / 277V / 347V

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Sure-Lites

Full directory →

43 rep agencies carry the Cooper Lighting Solutions line across 51 states. Pick your state.