Sure-LitesEmergency Units

CU2-LED Series

The Sure-Lites CU2-LED Emergency Light is designed to reduce egress system cost and maintenance as well as improve reliability. Key features include long life LED’s, proprietary optics, and a nickel cadmium battery. The patented easy hang feature reduces installation time and cost.

compliance: UL 924family: CU2-LED Seriesvoltage: UNV

Cross-References

30 equivalents across 26 brands

Compare top 3
  • ParaflexPFX-5541partial

    The PARAFLEX PFX‑5541 is a decorative LED emergency lighting unit with universal 120–277V input, four 1.0‑watt LED heads, and a 90‑minute minimum runtime. It features a maintenance‑free NiMH battery, 5VA flame‑retardant thermoplastic housing, and is UL listed for damp locations. An optional self‑diagnostic feature is available.

    • category
    • environment
    • voltage
    spec →
  • LiteLumeLL-LEDXRpartial

    LED High Output Industrial Remote Capable Thermoplastic Emergency Unit Ultra-bright, energy efficient, long-life White LED adjustable lamp heads provide up to 100-ft center-to center spacing with a 6-ft path of egress at 15-ft mounting height. 6.0 watt (12 LEDs x 0.50 watt) per head. Adjustable glare-free PAR-Type lamp heads with all inclusive lamp, reflector and lens assembly.

    • category
    • environment
    • voltage
    spec →
  • Atlas LightingOVAL-2-HEADED-EMERGENCY-LIGHTpartial

    The EMO2A Series features two LED fully adjustable lamp heads in a contemporary design. quick installation and premium options, in a stylish and economical package. This fixture offers quick installation and premium options in a stylish and economical package.

    • category
    • environment
    • voltage
    spec →
  • H.E. WilliamsEMER-CP-ADJ-LEDpartial

    With two adjustable LED lamp heads of the EMER/CP/ADJ/LED allows the customer the ability to orient emergency lighting to the optimal angle for any given situation. The 3.6V long-life rechargeable NiCd battery provides the unit with 90 minutes of emergency operation.

    • category
    • environment
    • voltage
    spec →
  • IsoliteBAL1400ACTDpartial

    The BAL-1400ACTD Emergency Fluorescent Ballast works with or without an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting.

    • category
    • environment
    • voltage
    spec →
  • MyersEPC-2-D-FMpartial

    The EPC-2-D-FM Emergency Power Control allows users to convert normal light fixtures into approved emergency lights. Learn more about its features.

    • category
    • environment
    • voltage
    spec →
  • LithoniaELM2L-EMERGENCY-UNITpartial

    The ELM2L Series from the Lithonia Lighting® Quantum® Family is a thermoplastic, dual round head emergency unit allowing for maximized spacing between units down long hallways and open spaces. ELM2L

    • category
    • environment
    • voltage
    spec →
  • Branch Circuit Emergency Lighting Control Transfer Switch Lighting

    • category
    • environment
    • voltage
    spec →
  • ExitronixLED-51/52partial

    General Purpose · Emergency Lighting

    • category
    • environment
    • voltage
    spec →
  • BodineBLCD-20Bpartial

    Bodine Emergency Switch Bypass Devices, | Bodine

    • category
    • environment
    • voltage
    spec →
  • HolophaneCZQ6L-EMERGENCY-LIGHTpartial

    The CZQ6L from Holophane® is an aesthetically pleasing emergency LED light fixture. It provides a minimum of 90 minutes of illumination with constant light output when there is a loss of power.

    • category
    • environment
    • voltage
    spec →
  • Power SentryPS1400QD-MVOLTpartial

    The PS1400QD MVOLT by IOTA® provides reliable emergency lighting in a compact design suited for low-profile troffers, downlights, and industrial luminaires. The emergency ballast includes a

    • category
    • environment
    • voltage
    spec →
  • Pathway ConnectivityPWEMDMX-EMERGENCY-DMX-CONTROLLERpartial

    The Pathway DMeXit is a UL924 compliant controller designed to send a control signal to DMX lighting in emergencies to satisfy minimum luminance levels for egress lighting. Using a wet or dry contact

    • category
    • environment
    • voltage
    spec →
  • TechlightEb7 T5partial

    The EB7T5 fluorescent emergency ballast works in conjunction with the AC ballast to covert new or existing fluorescent fixtures into emergency lighting. When AC power fails, the EB7T5 immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.

    • category
    • environment
    • voltage
    spec →
  • The SENSORWORX Emergency Power Control device provides a simple method of converting standard light fixtures into emergency light fixtures for a UL924 compliant emergency application. The SWX-EPC-A-2 family ensures compliance with both life safety and energy codes and eliminates the wasted energy that is used when emergency lighting is kept on 24 hours a day. These devices have both ears and a chase nipple, allowing them to be mounted in a variety of places as needed.

    • category
    • environment
    • voltage
    spec →
  • Purpose-built for lighting & video wall installations LynTec’s new LCP panel series is made for lighting and video wall applications. Based on the Square D G3 Powerlink breaker, the LCP brings you the lighting features you need with the performance that you trust. This makes the new LCP series panel one of the most cost-effective and easy-to-use power control options on the market today. DMX, sACN and IP-based Control at Your Fingertips Built-in web server with browser interface. Set up, control and monitor via smart phone, tablet or computer. Interface with any control system that communicates individual circuit addresses in IP, DMX-512, sACN or contact closures for light sensors, motion sensors or switch sets. Your Systems Your Way Enable up to 12 zones with each zone controlled by a unique protocol Create up to four sets of unique DMX-512 or sACN addresses for control Individually control circuits using unique addresses individually assigned or control entire zones using a single DMX or sACN address to free up addresses for other uses. UL-924 Capable for Emergency Ingress/Egress lighting Built-in scheduling program with an astronomical clock that has up to 84 available schedules including Sunrise, Sunset and multiple schedules controlling individual zones for complete customization Fully Customizable 30-84 space, 100-600A MLO and MCB panels as well as narrow profile panels Motorized breakers in 15, 20 and 30 amps, 1, 2 and 3 poles Optional Integrated SPD and SurgeX in-panel surge elimination modules Based on Square D’s latest generation of motorized breaker technology, each breaker is rated for 200,000 on/off/on cycles and has a mean time to failure of 900,000 on/off/on cycles Substantial installation labor savings over any other system available

    • category
    • environment
    • voltage
    spec →
  • LuminosoLE WPL 2 F W Nweak

    Injection-molded thermoplastic ABS housing

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV277V
    spec →
  • UltraLITE Model ELU (1.5kW to 14kW)

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV120347
    spec →
  • nLightDCHUBweak

    The DCHUB is a required component of the DC2DC Architecture. Distributes Class 2 low voltage DC power to DC-powered LED luminaires, including support for either all emergency lighting or all

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV120V
    spec →
  • Ease of Installation and Maintenance

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV277V
  • TivoliECLIPSEWALLweak

    The Eclipse Wall is an indirect wall safety lighting system. Its ideal applications are interior walkways, egress, walkways, and stairs.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV277V
    spec →
  • Nora LightingNSEM6WDweak

    A surface mount enclosure with an emergency LED driver for use with 6" ELO and ELO+ luminaires. It adds 1-1/2" height to the luminaire and matches the finish. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Compatible with 6" ELO & ELO+ Matching decorative enclosure also available Listed for field installation - UL 924 and CSA C2.22 No 141 Includes integral test switch ELECTRICAL Input Voltage: 120VAC, 50/60Hz Output Voltage: 123/131VDC Wattage: 3W Illumination Time: 90 minutes OPERATION When AC power fails, the driver immediately switches to the emergency mode, operating the LEDs at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency driver automatically returns to the charging mode. BATTERY Ternary lithium-ion battery requires 24 hours to recharge. COMPATIBLE LUMINAIRES NELO-6RTWMPW: 6" ELO with Selectable CCT, 1050lm / 15W, 90+ CRI (use NELO-6RW to match finish) NELOCAC-6RP: 6" ELO+ with Dedicated CCT, 700lm / 12W, 90+ CRI MATCHING DECORATIVE ENCLOSURE NSEM-6ND: Decorative Enclosure without Emergency Driver

    • category
    • environment
    • mounting
    • voltage
    • spec delta
    • voltage: UNV120V
    spec →
  • Trace-LiteLE-C6weak

    Trace-Lite · LiteLogic · Bluetooth Controls · Power Adapters / Controllers

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV277V
    spec →
  • ELCO LightingKEM-LDweak

    Single whip for J-Box mounting. 90 minutes of emergency light. 120/277V AC, 60Hz. Bottom lead

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV120V/277V
  • Intelligent Lighting ControlsLLxx-EM UL924 Relay Panelweak

    The LightLEEDer Emergency UL 924 bypass relay control panel will force relay's ON during a normal power outage. This panel has all the same features and functions as a standard LightLEEDer lighting controller, allowing normal control of relays with emergency bypass during a normal power failure event. Relays can be all EM or a combination of normal and EM. Each output has a jumper for selecting Force On, Force Off or No change, this allows for emergency on, load shedding off, or no control selection for each relay. Provided With Phase monitoring module and high voltage dividers. This LightLEEDer Emergency lighting panel is easy to install, no external devices or complicated wiring configurations needed, reducing material and installation costs.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV120/277VAC
    spec →
  • This flexible fixture can be used in numerous applications as the lumens and options allow it to be used as a replacement for industrial strips, vanity lighting, stairwells, retail and hallway applications. Options include occupancy sensors, tandem wiring to permit continuous rows, emergency lighting, and CCT Selectable.

    • category
    • environment
    • voltage
    • spec delta
    • voltage: UNV90-305V
    spec →
  • ParaflexPFX-5548partial

    PFX-5548 LED Recessed Emergency Unit Ultra-bright, energy-efficient LED heads provide up to 50 ft spacing with 1.0 W per head. Universal 120–277 VAC input with LED status indicators and push-to-test switch. NiMH battery with solid-state transfer delivers 90 minutes of emergency illumination and recharges in 24 hours. Includes bar hangers for drywall or drop-ceiling mounting. 5VA flame-retardant thermoplastic housing with oval and rectangular trim plates in white or black. Designed for discreet recessed installation and reliable performance in commercial environments. Ideal for corridors, offices, and areas requiring code-compliant emergency egress lighting.

    • category
    • environment
    • voltage
    spec →
  • LiteLumeLL-SRHLEDpartial

    Indoor Steel LED Remote Head Long lasting, efficient, ultra bright white LED lamp heads. High performance chrome-plated metallized reflector and glass lens for optimal light distribution Adjustable 6V 5.3W lamp heads increases center-to center spacing. LED Emergency Lighting

    • category
    • environment
    • voltage
    spec →
  • H.E. WilliamsEMER-LEDpartial

    EMER/LED features high-performance reflectors, plastic lensing, and ultra-bright white LEDs to provide optimal light distribution for emergency situations.

    • category
    • environment
    • voltage
    spec →
  • IsoliteCELpartial

    The CEL is a city of Chicago Approved Emergency Light. It has two top-mounted lamps with a pc lens to provide optimal light distribution.

    • category
    • environment
    • voltage
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Sure-Lites

Full directory →

43 rep agencies carry the Cooper Lighting Solutions line across 51 states. Pick your state.

Line cards are directional — confirm coverage with the agency before routing a spec.