Mule LightingExit Signs

CHSX SERIES

The CHSX Series is a low-profile, compact LED illuminated exit sign for the City of Chicago available in AC-only or self-powered models that operates for a minimum of 90 minutes during a power outage. The CHSX Series features a Lithium Ion class battery coupled with durable 20 gauge steel construction with a UL 924 compliant single-face EXIT glass panel in an attractive styling for ceiling, end, pendant or wall mount applications. A full range of alternative glass panels are available as accessories.

compliance: UL 924voltage: 120V/277Vfamily: CHSX SERIESwattage: 6.8housing material: steel

Cross-References

Top equivalents — 12 across 12 brands

Compare top 3
  • ParaflexPFX-5513partial

    PFX 5513 New York City Approved Steel LED Exit Sign. Ultra bright, energy efficient, long life Red LED. New York City compliant 8” EXIT letters.

    • category
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 120V/277VUNV
    spec →
  • Sure-LitesES6partial

    The Sure-Lites ES Series of surface-mounted Exits are designed for architectural excellence and minimal presence. The brushed aluminum housing presents a clean architectural appearance that compliments virtually any interior space. The crystal clear, wedge-shaped panel allows architectural details to shine through while providing excellent light distribution and exit visibility. Long-life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance.

    • category
    • environment
    • voltage
    • housing
    • spec delta
    • voltage: 120V/277V277V
    spec →
  • LithoniaTCE-EXIT-SIGNpartial

    The TCE Series from the Lithonia Lighting® Indura® Family is ideal for City of Chicago applications requiring a steel exit sign. The TCE is constructed out of 20-gauge steel with a white powder coat

    • category
    • environment
    • voltage
    • wattage
    • housing
    • spec delta
    • voltage: 120V/277V120-347V
    spec →
  • Advantage Environmental LightingEM2216WETLOCATIONSEMIRECESSEDMR16EMERGENCYUNIT2partial

    ILLUMINATION • Two fully adjustable, ultra-bright, round, 7.2W MR-16 halogen lamp heads with a fully gasketed enclosure and clear polycarbonate lens cover. ELECTRICAL • Dual 120/277 voltage. • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing. • LVD (low voltage disconnect) prevents battery from

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 120V/277VUNV
    spec →
  • Chloride11572518partial

    The CWU Series is a wet location emergency unit. Featuring a high impact resistant thermoplatic housing with integrated LED lamps, the CWU series can be wall mounted in a variety of applications and environment

    • category
    • environment
    • mounting
    • voltage
    • wattage
    • spec delta
    • voltage: 120V/277VUNV
    spec →
  • Solas Ray LightingSRWLUEpartial

    SRWLUE Series - Semi-Recessed LED Emergency Lighting

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 120V/277VUNV
    spec →
  • Amico LightingA06SP01AM0106015partial

    IP65 Waterproof - Featuring a fully sealed lampshade, this emergency light is built to withstand outdoor rain and wind, as well as indoor humidity. Its robust construction ensures reliable operation in diverse environments. Rotatable LED Light Heads - The LED light heads rotate 360° horizontally and 90° vertically for precise directional control. Combined with a 120° wide beam angle, they effectively illuminate large areas to meet diverse emergency lighting needs.

    • category
    • environment
    • voltage
  • Bartco LightingBC8781partial

    3" x 6" direct/indirect LED luminaire The BC8781 direct/indirect suspended linear luminaire features three light sources within a unique 3” high by 6” wide trapezoidal form factor. Each leg of the isosceles trapezoid contains a 3” wide diffuse light source. A 1-1/4” wide source located on the lower base directs light downward with options of a regressed acrylic diffuser or flat blade louver optic.

    • category
    • environment
    • voltage
    spec →
  • Genlyte SolutionsCWU - Wet Location Emergency Unitpartial

    The CWU Series is a wet location emergency unit. Featuring a high impact resistant thermoplatic housing with integrated LED lamps, the CWU series can be wall mounted in a variety of applications and environment

    • category
    • environment
    • mounting
    • voltage
    • wattage
    • spec delta
    • voltage: 120V/277VUNV
    spec →
  • Soft Green Exit Signs and Emergency Lights The GLE-S Green Exit Series is specifically designed to provide plant-safe Soft Green egress lighting for horticultural applications. The plant-safe, green light provides a safe means of egress while not adversely affecting plant growth during dark cycles. The GLE-S is the brightest, most visible sign in the industry in both normal and smoke-filled environments. The GLE-S is a UL code-compliant exit sign which emits a plant-safe, Soft Green light perfect for use in grow rooms. Commercial grow rooms must meet code compliance for proper exit signage while maintaining the integrity of the dark cycle.

    • category
    • environment
    • voltage
    • spec delta
    • wattage: 6.8W1.6W
    spec →
  • Halco Lighting10310partial

    Halco # 10310 Battery Backup Emergency 8W 120 277V Lifep04 Battery 90 Minute Backup BBU/EM8WU

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 120V/277V277V
  • LightalarmsLAXC LED Seriespartial

    About us | Literature |

    • category
    • environment
    • voltage
    • wattage
    • spec delta
    • voltage: 120V/277V277V
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Mule Lighting

Full directory →

47 rep agencies carry the Mule Lighting line across 50 states. Pick your state.

+40 more states in the full directory →

Line cards are directional — confirm coverage with the agency before routing a spec.