EXIT SIGN - SERIES EXWL
WET LOCTION BUY AMERICA OPTION Red or green letters. Field selectable knockout chevron directional indicators. Options include an internal heater.
Cross-References
30 equivalents across 18 brands
Compare top 3 →- spec →
The LPXW series provides a UL924 compliant solution for outdoor exit requirements. The fixture is wet location listed with a temperature rating of (- 20°C to 50°C ). The UV stabilized polycarbonate housing is available in white, grey or black with red or green Exit letters. Labor savings self-diagnostics that perform required monthly and yearly testing are standard for the self-powered exits.
- category
- environment
- voltage
- housing
- spec →
The LX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Top, end or back
- category
- environment
- voltage
- spec →
Nora's new 20 gauge steel body exit units are suitable for rugged applications and New York City approved. Exit sign utilizing Light Emitting Diode (LED) modules as the primary light source for economy operation NX-550 includes a backup NiCad battery for 90 minutes operation under emergency applications where primary power source has been interrupted or terminated. NX-550-LED/R - Red Letters with White Housing NX-505-LED/RB - Red Letters with Black Housing BODY 14-5/8" Width X 10-1/2" Height X 2-1/4" Depth 20 gauge Steel construction Black & White finish FACE Single or double face 8" high text with 1" stroke Snap-out chevron New York approved MOUNTING Universal - Wall, side, or ceiling Mounting hardware and canopy included ELECTRICAL Voltage Dual 120V / 277V input (0.038A / 0.017A) Automatic solid state switching and charging Light Source Long life LED sources Battery NiCad (nickel-cadmium) 3.7 Watts @ 120V replaceable battery included 90 minute emergency operation Internal solid state charging circuit Testing High-charge/ready operation indicator light Test button Circuitry Protection Short circuit protection LIFE EXPECTANCY LED sources and PC circuitry are rated for approximately 25 years with no change in illumination level 5 year warranty on materials and workmanship APPROVALS UL Listed NFPA-101 Meets City of New York emergency code requirements (NY Approved) Suitable for damp location
- category
- environment
- voltage
Single or Double faced. 120V/277V with battery backup and hanger bars. For wall or ceiling mount. UL or ETL listed. Removable chevrons (arrows) included for jobsite customization.
- category
- environment
- voltage
- spec →
PFX 5503 Thin Thermoplastic EXIT Sign. Ultra bright, energy efficient, long life Red or Green LEDs. Dual 120/277 voltage. • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing. 1.2V long life, maintenance-free, rechargeable NiCd battery (EM models only). Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
- spec →
Low-Profile wet location Exit and Emergency combo unit, 2.5" deep. Available in white, black and grey. Stocked in selectable Red/Green for convenience. Long lasting, efficient, ultra bright white LED lamp heads. 1.0W (1 LEDs x 1.0 watt) per head. Adjustable LED lamp heads provide up to 18-ft center-to center spacing with 3-ft path of egress at 7.5-ft mounting height.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
- spec →
Our Edge-Lit features an integrated and pivot system that allows it to be installed on the wall, ceiling or sloped surface. Available in Red or Green lettering, single face on mirrored acrylic panel
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 277V
- spec →
The Rival RXD Series Die-cast Exit features aluminum housing with canopy and a brushed aluminum face. It has dual voltage input to meet a variety of needs. Long-life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. The premium sealed nickel cadmium batteries have a 15-year life expectancy. With ceiling, wall and end mounting the Rival RXD Series can meet any design needs. Universal, field-selectable chevrons add versatility. This series is UL damp location listed (indoor).
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 277V
- spec →
The Fail-Safe EXL offers buyers one of the best high-abuse, specification-grade exit signs on the market. Its architectural low profile combines 14-gauge steel and a 1/8-inch polycarbonate lens to withstand the toughest environments. The door attaches to the housing with four tamper-resistant fasteners. LEDs power the unit for energy-efficient, even illumination. These fixtures are UL/cUL listed for damp locations. The EXL is specifically designed for use in public access areas where safety and security are critical; it is ideal for use in maximum security correctional facilities, public housing, schools, psychiatric wards, detention centers, military barracks, parks, and hospitals.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 120V
PRODUCT SPECIFICATIONS ILLUMINATION • Two, 6V/12V adjustable bi-pin halogen lamp heads. ELECTRICAL • Dual 120V/277 voltage. • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing. • LVD (low voltage disconnect) prevents battery from deep discharge. • 6V Sealed lead acid, maintenance-free, rechargeable battery.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 120V/12DCV
- spec →
The Chloride AMS is an LED Architectural Message Sign with 4 faceplate styles and variety of mounting accessories. It is ideal for providing informational and warning messages in a wide range of architectural spaces. Used in Hospitals, X-ray Suites and other medical settings where it is critical to know if a space is occupied or not accesible to personnel.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
- spec →
The DLTLC from Holophane is a wet location low-profile combination of exit and emergency light. Available with red or green letters. It is ideal to safely illuminate the path of egress above-the-door
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
- spec →
This TCL Series EXIT HERE w/Down Arrows (120-277VAC) outdoor, blank-out sign is designed with super bright LEDs and a contrasting face; we guarantee it's readable in direct sunlight. The sign message is formed by visible LEDs on a black sign face and is designed to illuminate the message(s) when turned on and blank out or extinguish the message when off.It is engineered with a solid-state circuit board and switch-mode power supply for maximum LED life. The cabinet is constructed of corrosion-resistant, extruded aluminum and ships with our Lift'N Shift back for wall mounting. Ceiling, post and wall-projection mountings are available. Standard cabinet finish is Duranodic Bronze; custom paint finishes are available. Sign can be controlled by a switch or third-party relay. Control switch can be purchased separately. UL/cUL Listed for wet locations.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 120-277VAC
- spec →
The All-Pro APXH7 series is a polycarbonate LED exit with remote capacity. The series is compatible with the APWR1 and APWR2, 3.6 volt LED remotes. It is available with red or green letters. The APXH7R2 and APXH7G4 will power two LED remote heads while the APXH7R4 and APXH7G4 will power four remote heads. These exits are universal mount (ceiling, wall or end) and are field configurable for single or double face.
- category
- environment
- voltage
- spec →
Rugged 20 gauge steel luminaires comply with the latest New York City codes and performance standards. Stencil letters are 8" high with 1" stroke, with a minimum of 100' viewing distance rating as required by UL 924 standard. FEATURES Meets City of New York Emergency Code requirements 20-gauge steel housing with white powder coating Fully-illuminated 8" letters with 1" stroke Includes single and double faces Removable knockout chevron directional arrows Illuminates for 90 minutes during power failure Universal mounting (Wall or Side) HOUSING 20-gauge steel housing includes an additional face for a double-sided exit sign. Adjustable emergency heads feature a unique twist-locking collar. Low profile snap-together. Snap-out knockouts for wiring. MOUNTING Steel case includes two knockouts for side of wall mounting (hardware included). LABELS AND LISTINGS 5 year limited warranty Meets City of New York emergency code requirements (NY Approved) NFPA-101 cULus Listed for damp locations
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
- spec →
-Ultra-bright, energy efficient, long-lasting white LEDs provide uniform illumination. -UV stabilized, silk screened acrylic panels provide consistent, uniform illumination. -Premium-grade, extruded aluminum housing. -Extruded aluminum trim assembly is easily detachable, providing accessibility for service or maintenance. Also available in optional white finish. -Single or double face configurations.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 120V
- spec →
Injection-molded, engineering-grade, 5VA flame retardant, high-impact resistant, thermoplastic in white finish
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 277V
- spec →
The Marathon Series Exits are designed for architectural excellence and minimal presence. The crystal clear wedge-shaped panel allows architectural details to shine through while providing excellent light distribution and exit visibility. Long-life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 277V
- spec →
The Chicago-approved EXIT/CHICAGO exit sign can function as either a full-time AC powered unit or an emergency unit with battery backup.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →