EMERGENCY LIGHT - SERIES EMS
STEEL - REMOTE CAPABLE 24 Watt remote capacity. Black or white finish.
Cross-References
Top equivalents — 12 across 12 brands
Compare top 3 →All LED NEMA 4X NSF Exit & Emergency Combo Two fully adjustable, ultra bright 3.3 watt high performance MR-16 base LED lamp heads for optimized center-to-center spacing. Long-life, energy efficient Red or Green LED EXIT sign illumination. IP66 rated for Ingress protection
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120/277V → 120V
- spec →
The LPXW series provides a UL924 compliant solution for outdoor exit requirements. The fixture is wet location listed with a temperature rating of (- 20°C to 50°C ). The UV stabilized polycarbonate housing is available in white, grey or black with red or green Exit letters. Labor savings self-diagnostics that perform required monthly and yearly testing are standard for the self-powered exits.
- category
- environment
- voltage
- spec delta
- wattage: 27W → 3.4W
- spec →
The LX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Top, end or back
- category
- environment
- voltage
- housing
- spec delta
- wattage: 27W → 2W
- spec →
Nora's new 20 gauge steel body exit units are suitable for rugged applications and New York City approved. Exit sign utilizing Light Emitting Diode (LED) modules as the primary light source for economy operation NX-550 includes a backup NiCad battery for 90 minutes operation under emergency applications where primary power source has been interrupted or terminated. NX-550-LED/R - Red Letters with White Housing NX-505-LED/RB - Red Letters with Black Housing BODY 14-5/8" Width X 10-1/2" Height X 2-1/4" Depth 20 gauge Steel construction Black & White finish FACE Single or double face 8" high text with 1" stroke Snap-out chevron New York approved MOUNTING Universal - Wall, side, or ceiling Mounting hardware and canopy included ELECTRICAL Voltage Dual 120V / 277V input (0.038A / 0.017A) Automatic solid state switching and charging Light Source Long life LED sources Battery NiCad (nickel-cadmium) 3.7 Watts @ 120V replaceable battery included 90 minute emergency operation Internal solid state charging circuit Testing High-charge/ready operation indicator light Test button Circuitry Protection Short circuit protection LIFE EXPECTANCY LED sources and PC circuitry are rated for approximately 25 years with no change in illumination level 5 year warranty on materials and workmanship APPROVALS UL Listed NFPA-101 Meets City of New York emergency code requirements (NY Approved) Suitable for damp location
- category
- environment
- voltage
- housing
- spec delta
- wattage: 27W → 4.8W
- spec →
The CHUPS-G2 series by Chloride is a high-performance single-phase mini inverter system designed to meet critical power requirements, offering a power range of 175VA/W to 1100VA/W. Engineered for reliability, this system is UL924 listed and compatible with LED, fluorescent, incandescent and halogen lamp loads, while providing a standard runtime of 90 minutes. Equipped with advanced features and configurable options, the CHUPS-G2 series supports multiple communication protocols, making it an ideal solution for a wide range of applications.
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120/277V → 120V
Single or Double faced. 120V/277V with battery backup and hanger bars. For wall or ceiling mount. UL or ETL listed. Removable chevrons (arrows) included for jobsite customization.
- category
- environment
- voltage
- spec →
The HLEMC from Holophane® is a high-performing, IP66 rated emergency exit combo that is designed for use in Class 1, Div 2, groups A, B, C, & D hazardous environments, meeting up to a T3C temperature
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120/277V → 120V
- spec →
PFX 5503 Thin Thermoplastic EXIT Sign. Ultra bright, energy efficient, long life Red or Green LEDs. Dual 120/277 voltage. • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing. 1.2V long life, maintenance-free, rechargeable NiCd battery (EM models only). Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours.
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → UNV
Our Edge-Lit features an integrated and pivot system that allows it to be installed on the wall, ceiling or sloped surface. Available in Red or Green lettering, single face on mirrored acrylic panel
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 277V
- wattage: 27W → 2W
- spec →
The Rival RXD Series Die-cast Exit features aluminum housing with canopy and a brushed aluminum face. It has dual voltage input to meet a variety of needs. Long-life, energy-efficient LED lamps reduce energy costs and eliminate routine lamp maintenance. The premium sealed nickel cadmium batteries have a 15-year life expectancy. With ceiling, wall and end mounting the Rival RXD Series can meet any design needs. Universal, field-selectable chevrons add versatility. This series is UL damp location listed (indoor).
- category
- environment
- voltage
- spec delta
- voltage: 120/277V → 277V
- spec →
The Fail-Safe EXL offers buyers one of the best high-abuse, specification-grade exit signs on the market. Its architectural low profile combines 14-gauge steel and a 1/8-inch polycarbonate lens to withstand the toughest environments. The door attaches to the housing with four tamper-resistant fasteners. LEDs power the unit for energy-efficient, even illumination. These fixtures are UL/cUL listed for damp locations. The EXL is specifically designed for use in public access areas where safety and security are critical; it is ideal for use in maximum security correctional facilities, public housing, schools, psychiatric wards, detention centers, military barracks, parks, and hospitals.
- category
- environment
- voltage
- housing
- spec delta
- voltage: 120/277V → 120V
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →