Halco # 95004 Evade Exit Sign & Emergency Unit Combo Green Lettering EV-EXC-GR quality egress lighting solution for hallway, stairwell, and other Life Safety applications UL924 Code Life Safety
Cross-References
Top equivalents — 12 across 12 brands
Compare top 3 →- spec →
New York City Compliant Edgelit Aluminum Exit Sign Ultra bright, energy efficient, long life Red LEDs. UV-stabilized ultra-clear acrylic edgelit panel provides consistent, uniform illumination. Double face utilizes factory installed silver or white mylar background panel. New York City compliant 8” EXIT letters.
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → 120V
- cct: 5700K → 2700K
- spec →
The LPXW series provides a UL924 compliant solution for outdoor exit requirements. The fixture is wet location listed with a temperature rating of (- 20°C to 50°C ). The UV stabilized polycarbonate housing is available in white, grey or black with red or green Exit letters. Labor savings self-diagnostics that perform required monthly and yearly testing are standard for the self-powered exits.
- category
- environment
- voltage
- spec delta
- wattage: 8W → 3.4W
- spec →
The LX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Top, end or back
- category
- environment
- voltage
- spec delta
- wattage: 8W → 2W
- spec →
PRODUCT SPECIFICATIONS ILLUMINATION • Adjustable ultra-bright 8W bi-pin halogen lamp head. • Sealed beam PAR36-type gimbal trim with smooth chrome-plated metallized reflector and plastic lens offers optimal light distribution. ELECTRICAL • Dual 120/277 voltage. • Junction box with 3/4” knockouts for AC input. • Charge rate/power “ON” LED indicator light
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → UNV
- spec →
The PORTAL EXIT bollard delivers an exterior rated architectural solution for visual guidance and messaging. Suitable for outdoor applications ranging from rooftop pool decks and gardens to courtyards, the slender rectangular form integrates comfortably into a variety of architecture. The extruded aluminum bollard is available with green or red letters. Custom signage, logos, or patterns may also be incorporated on request. Concealed mounting plate assembly delivers a clean, flangeless appearance. All hardware is stainless steel. CSA Certified for Wet Locations and UL924 compliant.
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → UNV
- spec →
Nora's new 20 gauge steel body exit units are suitable for rugged applications and New York City approved. Exit sign utilizing Light Emitting Diode (LED) modules as the primary light source for economy operation NX-550 includes a backup NiCad battery for 90 minutes operation under emergency applications where primary power source has been interrupted or terminated. NX-550-LED/R - Red Letters with White Housing NX-505-LED/RB - Red Letters with Black Housing BODY 14-5/8" Width X 10-1/2" Height X 2-1/4" Depth 20 gauge Steel construction Black & White finish FACE Single or double face 8" high text with 1" stroke Snap-out chevron New York approved MOUNTING Universal - Wall, side, or ceiling Mounting hardware and canopy included ELECTRICAL Voltage Dual 120V / 277V input (0.038A / 0.017A) Automatic solid state switching and charging Light Source Long life LED sources Battery NiCad (nickel-cadmium) 3.7 Watts @ 120V replaceable battery included 90 minute emergency operation Internal solid state charging circuit Testing High-charge/ready operation indicator light Test button Circuitry Protection Short circuit protection LIFE EXPECTANCY LED sources and PC circuitry are rated for approximately 25 years with no change in illumination level 5 year warranty on materials and workmanship APPROVALS UL Listed NFPA-101 Meets City of New York emergency code requirements (NY Approved) Suitable for damp location
- category
- environment
- voltage
- spec →
The Chloride AMS is an LED Architectural Message Sign with 4 faceplate styles and variety of mounting accessories. It is ideal for providing informational and warning messages in a wide range of architectural spaces. Used in Hospitals, X-ray Suites and other medical settings where it is critical to know if a space is occupied or not accesible to personnel.
- category
- environment
- voltage
- wattage
- spec delta
- voltage: 120V/277V → UNV
IP65 Waterproof - Featuring a fully sealed lampshade, this emergency light is built to withstand outdoor rain and wind, as well as indoor humidity. Its robust construction ensures reliable operation in diverse environments. Rotatable LED Light Heads - The LED light heads rotate 360° horizontally and 90° vertically for precise directional control. Combined with a 120° wide beam angle, they effectively illuminate large areas to meet diverse emergency lighting needs.
- category
- environment
- voltage
- spec →
3" x 6" direct/indirect LED luminaire The BC8781 direct/indirect suspended linear luminaire features three light sources within a unique 3” high by 6” wide trapezoidal form factor. Each leg of the isosceles trapezoid contains a 3” wide diffuse light source. A 1-1/4” wide source located on the lower base directs light downward with options of a regressed acrylic diffuser or flat blade louver optic.
- category
- environment
- voltage
- spec delta
- cct: 5700K → 2700/3000/3500/4000K
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →
Local Reps
Who reps Halco Lighting
Full directory →15 rep agencies carry the Halco Lighting line across 30 states. Pick your state.
Alabama AL1 agency
Birmingham · Mobile
Alaska AK1 agency
Statewide
Arizona AZ1 agency
Statewide
California CA1 agency
Sacramento · San Francisco
Delaware DE1 agency
Statewide
District of Columbia DC1 agency
Statewide
Florida FL1 agency
Panhandle
Georgia GA1 agency
Atlanta · Savannah
Idaho ID1 agency
Boise
Indiana IN1 agency
Statewide
+20 more states in the full directory →