EvenliteEmergency Units

TEBL6W-SD

TEBL6 with self-test / self-diagnostics, white housing.

subcategory: commercial_thermoplastic_led_highfamily: Telesis TEBLvoltage: 120/277 VACwattage: 12Wbattery: 9.6V LiFePO4duration minutes: 90housing color: Whitelumens: 1300wattage spec: 6ip rating: IP65

Cross-References

24 equivalents across 9 brands

Compare top 3
  • LithoniaELM2L W M6strong

    Standard white ELM2L configuration for Contractor Select program.

    • category
    • voltage
    • duration
  • IsoliteBUGpartial

    The BUG High Performance LED Emergency Light is CEC Title 20 compliant. The BUG 3 produces 300 lumens and the BUG 6 produces 650 lumens in emergency lighting.

    • category
    • voltage
    • lumens
    • wattage
    • spec delta
    • voltage: 120/277 VACUNV
    spec →
  • ExitronixNFTpartial

    General Purpose · Specification · Emergency Lighting · CEC Compliant · California Offering (CEC)

    • category
    • voltage
    • lumens
    • wattage
    • spec delta
    • voltage: 120/277 VACUNV
    spec →
  • TechlightEb14partial

    The EB14 fluorescent emergency ballast works in conjunction with the AC ballast to covert new or existing fluorescent fixtures into emergency lighting. When AC power fails, the EB14 immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.

    • category
    • voltage
    • lumens
    • spec delta
    • voltage: 120/277 VACUNV
    • wattage: 6W17-215W
    spec →
  • PathLinx LED emergency light is aesthetically designed and offers features to reduce egress system cost. The thin profile emergency light unit blends into the environment with expanded egress light spacing between units, which provides a cost effective and unobtrusive emergency egress system. The expanded remote capability with wide coverage pattern and RJ45 connectors allows installers to reduce their cost of equipment, materials, and labor. The external battery disconnect and easy connection features make the PathLinx LED emergency light uncomplicated and efficient throughout installation.

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VACUNV
    spec →
  • Nora LightingNSEM6WDweak

    A surface mount enclosure with an emergency LED driver for use with 6" ELO and ELO+ luminaires. It adds 1-1/2" height to the luminaire and matches the finish. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Compatible with 6" ELO & ELO+ Matching decorative enclosure also available Listed for field installation - UL 924 and CSA C2.22 No 141 Includes integral test switch ELECTRICAL Input Voltage: 120VAC, 50/60Hz Output Voltage: 123/131VDC Wattage: 3W Illumination Time: 90 minutes OPERATION When AC power fails, the driver immediately switches to the emergency mode, operating the LEDs at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency driver automatically returns to the charging mode. BATTERY Ternary lithium-ion battery requires 24 hours to recharge. COMPATIBLE LUMINAIRES NELO-6RTWMPW: 6" ELO with Selectable CCT, 1050lm / 15W, 90+ CRI (use NELO-6RW to match finish) NELOCAC-6RP: 6" ELO+ with Dedicated CCT, 700lm / 12W, 90+ CRI MATCHING DECORATIVE ENCLOSURE NSEM-6ND: Decorative Enclosure without Emergency Driver

    • category
    • voltage
    • lumens
    • spec delta
    • voltage: 120/277 VAC120V
    • wattage: 6W15W
    spec →
  • ELCO LightingEE80Lweak

    Mini Emergency Light with two 2W fully adjustable glare-free square shape light heads for emergency light. Injection-molded thermoplastic ABS housing Innovative snap-together design allows for fast and easy installation. 250 lm (total) 3.6V, 1.5Ah battery pack for 90 minutes of emergency operation. LED Driver: 120V/277V AC, dual voltage operation integrated with LED bulb. cUL listed for damp location.

    • category
    • voltage
    • spec delta
    • wattage: 6W2W
  • The CZQ6L from Holophane® is an aesthetically pleasing emergency LED light fixture. It provides a minimum of 90 minutes of illumination with constant light output when there is a loss of power.

    • category
    • voltage
    • lumens
    • spec delta
    • voltage: 120/277 VACUNV
    • wattage: 6W32W
    spec →
  • Intelligent Lighting ControlsLLxx-EM UL924 Relay Panelweak

    The LightLEEDer Emergency UL 924 bypass relay control panel will force relay's ON during a normal power outage. This panel has all the same features and functions as a standard LightLEEDer lighting controller, allowing normal control of relays with emergency bypass during a normal power failure event. Relays can be all EM or a combination of normal and EM. Each output has a jumper for selecting Force On, Force Off or No change, this allows for emergency on, load shedding off, or no control selection for each relay. Provided With Phase monitoring module and high voltage dividers. This LightLEEDer Emergency lighting panel is easy to install, no external devices or complicated wiring configurations needed, reducing material and installation costs.

    • category
    • voltage
    • spec delta
    • wattage: 6W1W
    spec →
  • LithoniaEU2C W M6strong

    White-finish EU2C Basics emergency unit with square lamp heads.

    • category
    • voltage
    • duration
  • IsoliteCELweak

    The CEL is a city of Chicago Approved Emergency Light. It has two top-mounted lamps with a pc lens to provide optimal light distribution.

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VACUNV
    • lumens: 1300335
    spec →
  • ExitronixNFT-G3partial

    Exitronix · General Purpose · Specification · Emergency Lighting · Guardian G3 · Guardian G3 · Emergency Lights

    • category
    • voltage
    • lumens
    • wattage
    • spec delta
    • voltage: 120/277 VACUNV
    spec →
  • TechlightEb30weak

    The EB30 fluorescent emergency ballast works in conjunction with the AC ballast to covert new or existing fluorescent fixtures into emergency lighting. When AC power fails, the EB30 immediately switches to the emergency mode, keeping one or two lamps illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.

    • category
    • voltage
    • lumens
    • spec delta
    • voltage: 120/277 VACUNV
    • wattage: 6W17-215W
    spec →
  • Sure-LitesAEL2 Seriesweak

    The Sure-Lites Architectural Emergency Light is designed to provide superior illumination while blending into the surrounding space. The housing is constructed of die-cast aluminum with an integral refractive polycarbonate lens and advanced optical design, which in conjunction with energy-efficient, long-lasting LEDs provides maximum path of egress lighting performance. The Sure-Lites Architectural Emergency Light is wet listed for temperatures between -30°C and 50°C (-22°F and 122°F) and is available with Eagle Eye™ self diagnostics.

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VAC277V
    spec →
  • Nora LightingNEPK07LEDUNVweak

    Emergency LED driver for use with new or existing LED luminaires. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Listed for field installation - UL 924 and CSA C2.22 No 141 Class 2 output - UL 1310 certified, CSA 22.2 No 223-M91 Controlled power for predictable discharge 10 - 60VDC for wide range of LED loads Universal input (120 through 277VAC, 50/60Hz) Includes wall plate with test switch Certified to the energy efficiency standards of California Title 20 Accessory: NEPKA-07LEDFPTS: Replacement Remote Test Switch

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VAC277V
    spec →
  • ELCO LightingEE22Lweak

    Emergency Light with two Adjustable 1.5W LED glare free light heads. 120/277V. Universal mounting plate for fast and easy installation. Sturdy thermoplastic housing. Automatic switching from AC supply to battery power. Long life NiCad battery. cUL Listed for damp location.

    • category
    • voltage
  • The CZQ4L from Holophane® is an aesthetically pleasing emergency LED light fixture. It provides a minimum of 90 minutes of illumination when there is a loss of power. Equipped with four high

    • category
    • voltage
    • lumens
    • spec delta
    • voltage: 120/277 VACUNV
    • wattage: 6W32W
    spec →
  • LithoniaELM6Lpartial

    Highest-output ELM Quantum dual-head emergency unit at 1100 lumens. For large open areas requiring maximum coverage.

    • category
    • voltage
    • duration
    • spec delta
    • voltage: 120/277 VAC120-277V MVOLT
  • IsoliteE3MINIweak

    The E3MINI Pure Sine Wave Mini Inverter provides a field-selectable 120 or 277 VAC input/output. It is UL 924 and CSA 22.2 approved.

    • category
    • voltage
    • spec delta
    • wattage: 6W250W
    spec →
  • ExitronixCHIMweak

    Chicago Offering · Chicago Offering

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VAC277V
    • lumens: 1300396
    spec →
  • TechlightDlgweak

    The DLG Canopy light was designed as a high performance canopy light for parking garages. The removable upper reflector allows for uplight when elimnated. It is segmented to allow the installer to direct the light specifically to the points of egress and away from a driver’s direct line of sight.

    • category
    • voltage
    • spec delta
    • wattage: 6W175W
    spec →
  • Sure-LitesAEL246BZSDweak

    Sure-Lites Emergency Light Architectural

    • category
    • voltage
    • wattage
    • spec delta
    • voltage: 120/277 VAC277V
    spec →
  • Nora LightingNEPK23LEDUNVweak

    Emergency LED driver for use with new or existing LED luminaires. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Listed for field installation - UL 924 and CSA C2.22 No 141 Controlled power for predictable discharge Includes wall plate with test switch Input Voltage: 120-277VAC Output Voltage: 120VAC (during emergency operation) Output Wattage: 23W Compatible Luminaires: NCSC: 4" & 6" Contractor Series Can-less Downlights NCSD: 6" Contractor Series Disk Lights NCSR: 4" & 6" Contractor Series Retrofits NEFLINTW: 4" & 6" FLIN Can-less Regressed Baffle Downlights NELOSW: 4", 6" & 8" ELO Surface Mounts with Selectable Lumens & CCT NFLAT: 4" & 6" FLAT Can-less Non-Metallic Downlights NFLINA: 4" & 6" FLIN Can-less Adjustable Downlights NFRC: 4" & 6″ Fire Rated Can-less Downlights NJCB-12: 2" & 4" Iolite Can-less Driver Box NLCBC2: 4", 5" & 6" Cobalt Click Retrofits with Selectable CCT NLRS: 6" Sloped Retrofits NLOPAC-R6REGT24TW: 6" Regressed Opal Surface Mount NLOPAC2-R6509T24: 6" Opal 2 Surface Mount NLOS: 4", 6" & 7" SURF Surface Mounts NLTH: 4", 6" & 8" Theia Can-less Downlights NM1-PRDC: 1" M1+ Can-less Downlight NM2: 2" M2 Can-less Downlights NM4: 4" M4 Can-less Downlights NMC: 4" & 6" M-Curve Can-less Adjustable Downlights NMW: 2" & 4" M-Wave Can-less Adjustable Downlights NOXAC-431TW: 4" Onyx Retrofit Reflector with Selectable CCT NOXAC-432TW: 4" Onyx Retrofit Baffle with Selectable CCT NOXAC-4RGTW: 4" Onyx Adjustable Retrofit with Selectable CCT NOXAC-4RWTW: 4" Onyx Round Wall Wash Retrofit with Selectable CCT NOXAC-4SWTW: 4" Onyx Square Wall Wash Retrofit with Selectable CCT NOXAC-5631TW: 5"/6" Onyx Retrofit Reflector with Selectable CCT NOXAC-5632TW: 5"/6" Onyx Retrofit Baffle with S

    • category
    • voltage
    spec →
  • ELCO LightingKEM-LDweak

    Single whip for J-Box mounting. 90 minutes of emergency light. 120/277V AC, 60Hz. Bottom lead

    • category
    • voltage

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →

Local Reps

Who reps Evenlite

Full directory →

52 rep agencies carry the Evenlite line across 51 states. Pick your state.

Line cards are directional — confirm coverage with the agency before routing a spec.