DP
Fully recessed, self-contained emergency lighting fixture for ceiling or wall installation.
Cross-References
Top equivalents — 12 across 11 brands
Compare top 3 →- spec →
With spacing up to 55 ft in 9 ft ceilings, this recessed down light with a 4" trim is the most efficient emergency luminaire; very effective in long corridors, it is inconspicuous and will blend with general lighting fixtures without affecting the appearance of ceiling layouts.
- category
- mounting
Highest-output ELM Quantum dual-head emergency unit at 1100 lumens. For large open areas requiring maximum coverage.
- category
- voltage
- duration
- spec delta
- voltage: 120/277 VAC → 120-277V MVOLT
- spec →
The 15" Terrapin LED provides exceptional aesthetics with impressive strength and is available in 20, 30 or 40 watt lumen packages. Polycarbonate lens, clear or opal, combined with four face plates provides a choice of different styles. Choose a photocell or motion sensor for control. Select an emergency battery pack to provide egress illumination.
- category
- voltage
- wattage
- spec delta
- voltage: 120/277 VAC → UNV
- spec →
The WKP Wal-Pak Full Cutoff provides a durable and efficient exterior light source for any application requiring maximum performance and minimum maintenance. The rugged, die-cast aluminum housing, stainless steel hardware and gasket sealed optics compartment combine to make the Wal-Pak virtually impenetrable to contaminants.
- category
- voltage
- wattage
- spec delta
- voltage: 120/277 VAC → UNV
- spec →
The Sure-Lites LED Emergency Battery Pack EBPLEDL series allows LED luminaires to be used for emergency lighting when power fails. When a power failure occurs, the EBPELDL switches the luminaire to emergency mode and provides 90 minutes of power for emergency egress lighting. The series are UL924 listed for field retrofit installation and are compatible with Cooper Lighting Solutions LED fixtures. The constant power feature ensures consistent light output for a minimum of 90 minutes.
- category
- voltage
- housing
- spec delta
- wattage: 42W → 14W
- spec →
Universal New Construction Downlight. Product Category : 4-Inch Downlight; Product Type : Downlight; Product Shape : Round; Housing : New Construction; Environment : Damp Location; Compliance : ENERGY STAR® Certified,Certified to UL924 Standard for Emergency Lighting; Correlated Color Temperature : 2700K,3000K,3500K,4000K; Color Rendering Index : 80-89,90-100
- category
- voltage
- wattage
- spec delta
- voltage: 120/277 VAC → 120V
- spec →
Emergency LED driver for use with new or existing LED luminaires. Driver’s circuitry automatically switches the luminaire between emergency and normal power operation during power loss and restoration. Operates at a reduced level for a minimum of 90 minutes to allow safe egress during power outage. Upon restoration to normal AC operation, the emergency driver returns to charging mode. FEATURES Listed for field installation - UL 924 and CSA C2.22 No 141 Controlled power for predictable discharge Includes wall plate with test switch Input Voltage: 120-277VAC Output Voltage: 120VAC (during emergency operation) Output Wattage: 23W Compatible Luminaires: NCSC: 4" & 6" Contractor Series Can-less Downlights NCSD: 6" Contractor Series Disk Lights NCSR: 4" & 6" Contractor Series Retrofits NEFLINTW: 4" & 6" FLIN Can-less Regressed Baffle Downlights NELOSW: 4", 6" & 8" ELO Surface Mounts with Selectable Lumens & CCT NFLAT: 4" & 6" FLAT Can-less Non-Metallic Downlights NFLINA: 4" & 6" FLIN Can-less Adjustable Downlights NFRC: 4" & 6″ Fire Rated Can-less Downlights NJCB-12: 2" & 4" Iolite Can-less Driver Box NLCBC2: 4", 5" & 6" Cobalt Click Retrofits with Selectable CCT NLRS: 6" Sloped Retrofits NLOPAC-R6REGT24TW: 6" Regressed Opal Surface Mount NLOPAC2-R6509T24: 6" Opal 2 Surface Mount NLOS: 4", 6" & 7" SURF Surface Mounts NLTH: 4", 6" & 8" Theia Can-less Downlights NM1-PRDC: 1" M1+ Can-less Downlight NM2: 2" M2 Can-less Downlights NM4: 4" M4 Can-less Downlights NMC: 4" & 6" M-Curve Can-less Adjustable Downlights NMW: 2" & 4" M-Wave Can-less Adjustable Downlights NOXAC-431TW: 4" Onyx Retrofit Reflector with Selectable CCT NOXAC-432TW: 4" Onyx Retrofit Baffle with Selectable CCT NOXAC-4RGTW: 4" Onyx Adjustable Retrofit with Selectable CCT NOXAC-4RWTW: 4" Onyx Round Wall Wash Retrofit with Selectable CCT NOXAC-4SWTW: 4" Onyx Square Wall Wash Retrofit with Selectable CCT NOXAC-5631TW: 5"/6" Onyx Retrofit Reflector with Selectable CCT NOXAC-5632TW: 5"/6" Onyx Retrofit Baffle with S
- category
- voltage
- spec delta
- wattage: 42W → 9W
- spec →
Mini Emergency Light with two 2W fully adjustable glare-free square shape light heads for emergency light. Injection-molded thermoplastic ABS housing Innovative snap-together design allows for fast and easy installation. 250 lm (total) 3.6V, 1.5Ah battery pack for 90 minutes of emergency operation. LED Driver: 120V/277V AC, dual voltage operation integrated with LED bulb. cUL listed for damp location.
- category
- voltage
- spec delta
- wattage: 42W → 2W
- spec →
The LightLEEDer Emergency UL 924 bypass relay control panel will force relay's ON during a normal power outage. This panel has all the same features and functions as a standard LightLEEDer lighting controller, allowing normal control of relays with emergency bypass during a normal power failure event. Relays can be all EM or a combination of normal and EM. Each output has a jumper for selecting Force On, Force Off or No change, this allows for emergency on, load shedding off, or no control selection for each relay. Provided With Phase monitoring module and high voltage dividers. This LightLEEDer Emergency lighting panel is easy to install, no external devices or complicated wiring configurations needed, reducing material and installation costs.
- category
- voltage
- spec delta
- wattage: 42W → 1W
- spec →
The EB7T5 fluorescent emergency ballast works in conjunction with the AC ballast to covert new or existing fluorescent fixtures into emergency lighting. When AC power fails, the EB7T5 immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the ballast automatically returns to the charging mode.
- category
- voltage
- wattage
- spec delta
- voltage: 120/277 VAC → UNV
- spec →
A powerful LED fixture designed for very low profile recessed ceiling mount, or optional surface mount, suitable for interior locations, at heights over 40 ft from floor level. Dual function operation in either emergency or optional normal on mode, powered from the Sage central battery at 24VDC.
- category
- mounting
Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →
Local Reps
Who reps Evenlite
Full directory →52 rep agencies carry the Evenlite line across 51 states. Pick your state.
Alabama AL1 agency
- Lighting PartnershipCurrent
Birmingham · Mobile
Alaska AK1 agency
- Alaska Architectural LightingAcuity Brands
Statewide
Arizona AZ1 agency
- R.C. LurieAcuity Brands
Statewide
Arkansas AR1 agency
Statewide
California CA3 agencies
- ALRSignify (Philips)
Fresno · Sacramento · San Francisco
- OCS Lighting & ControlCurrent
San Diego
- PLP SoCalCurrent
Los Angeles · Ventura
Colorado CO1 agency
- The Lighting AgencyAcuity Brands
Statewide
Connecticut CT1 agency
- illuminateCurrent
Statewide
Delaware DE1 agency
Statewide
District of Columbia DC1 agency
- Chesapeake LightingCooper (Eaton)
Statewide
Florida FL5 agencies
- Power & Lighting SystemsAcuity Brands
Miami
- Lighting Partners of Central FloridaCooper (Eaton)
Orlando
- Tampa Bay LightingCooper (Eaton)
Tampa
Jacksonville
- Karl Volk & Co.
Panhandle
+41 more states in the full directory →
Line cards are directional — confirm coverage with the agency before routing a spec.