Amico LightingExit Signs

A21SP04AM002

Security First - Our emergency lights have two adjustable LED lamp heads, providing ample lighting at multiple ranges. Emergency lights become your safety savers when there are power outages, fires, or other emergencies from accidents.

compliance: UL 924voltage: 120V/277Vfamily: Emergency Lights for Business, with Battery Backup,Hard Wired, UL 924 Certified,AC 120/277V,Two Head Adjustable LED Emergency Lighting

Cross-References

Top equivalents — 12 across 12 brands

Compare top 3
  • Sure-LitesLPXW Seriespartial

    The LPXW series provides a UL924 compliant solution for outdoor exit requirements. The fixture is wet location listed with a temperature rating of (- 20°C to 50°C ). The UV stabilized polycarbonate housing is available in white, grey or black with red or green Exit letters. Labor savings self-diagnostics that perform required monthly and yearly testing are standard for the self-powered exits.

    • category
    • environment
    • voltage
    spec →
  • LithoniaLX-NY-EXIT-SIGNpartial

    The LX-NY Series from the Lithonia Lighting® Indura® Family is ideal for New York applications where steel exits is required. Available in a white finish. Dual Volt (120/277V) Top, end or back

    • category
    • environment
    • voltage
    spec →
  • Nora LightingNX550LEDpartial

    Nora's new 20 gauge steel body exit units are suitable for rugged applications and New York City approved. Exit sign utilizing Light Emitting Diode (LED) modules as the primary light source for economy operation NX-550 includes a backup NiCad battery for 90 minutes operation under emergency applications where primary power source has been interrupted or terminated. NX-550-LED/R - Red Letters with White Housing NX-505-LED/RB - Red Letters with Black Housing BODY 14-5/8" Width X 10-1/2" Height X 2-1/4" Depth 20 gauge Steel construction Black & White finish FACE Single or double face 8" high text with 1" stroke Snap-out chevron New York approved MOUNTING Universal - Wall, side, or ceiling Mounting hardware and canopy included ELECTRICAL Voltage Dual 120V / 277V input (0.038A / 0.017A) Automatic solid state switching and charging Light Source Long life LED sources Battery NiCad (nickel-cadmium) 3.7 Watts @ 120V replaceable battery included 90 minute emergency operation Internal solid state charging circuit Testing High-charge/ready operation indicator light Test button Circuitry Protection Short circuit protection LIFE EXPECTANCY LED sources and PC circuitry are rated for approximately 25 years with no change in illumination level 5 year warranty on materials and workmanship APPROVALS UL Listed NFPA-101 Meets City of New York emergency code requirements (NY Approved) Suitable for damp location

    • category
    • environment
    • voltage
    spec →
  • ELCO LightingEDGRECpartial

    Single or Double faced. 120V/277V with battery backup and hanger bars. For wall or ceiling mount. UL or ETL listed. Removable chevrons (arrows) included for jobsite customization.

    • category
    • environment
    • voltage
    spec →
  • Bartco LightingBC8781partial

    3" x 6" direct/indirect LED luminaire The BC8781 direct/indirect suspended linear luminaire features three light sources within a unique 3” high by 6” wide trapezoidal form factor. Each leg of the isosceles trapezoid contains a 3” wide diffuse light source. A 1-1/4” wide source located on the lower base directs light downward with options of a regressed acrylic diffuser or flat blade louver optic.

    • category
    • environment
    • voltage
    spec →
  • Soft Green Exit Signs and Emergency Lights The GLE-S Green Exit Series is specifically designed to provide plant-safe Soft Green egress lighting for horticultural applications. The plant-safe, green light provides a safe means of egress while not adversely affecting plant growth during dark cycles. The GLE-S is the brightest, most visible sign in the industry in both normal and smoke-filled environments. The GLE-S is a UL code-compliant exit sign which emits a plant-safe, Soft Green light perfect for use in grow rooms. Commercial grow rooms must meet code compliance for proper exit signage while maintaining the integrity of the dark cycle.

    • category
    • environment
    • voltage
    spec →
  • Halco Lighting90313partial

    Halco # 90313 Battery Backup Emergency 9W 120-277V 90 Minute 0-10V Dimming BBU/EM9WU

    • category
    • environment
    • voltage
  • LSI IndustriesMLIpartial

    Designed for flexibility of installation, the MLI microlight inverter is a single-phase, standby, solid-state lighting inverter system. The MLI is designed to function in conjunction with the existing building electrical system to provide backup power protection and distribution for lighting loads in the event of utility power failure.

    • category
    • environment
    • voltage
    spec →
  • Mule LightingC1D2-Cpartial

    The Class 1, Div. 2 Combo unit is designed for harsh ans hazardous environments. The vandal resistant NEMA 4X rated housing is suitable for wet locations.

    • category
    • environment
    • voltage
    spec →
  • NICOR LightingEOF1MV5KSVPpartial

    The LED Emergency Outdoor Full Cutoff combines 90-minute emergency lighting with a low-profile, architectural design. The EOF is designed for outdoor use, with an optional cold-weather kit for added reliability in northern climates. The EOF comes standard with a photocell and wall switch, allowing users added energy efficiency and the ability to control the light from a switch, with an optional motion sensor adding even more energy efficiency. A non-emergency unit is available for locations not requiring battery-backup, providing a uniform look for all fixtures.

    • category
    • environment
    • voltage
    spec →
  • ValriyaVA-CESRUpartial

    The CESRU Series features a field-selectable color, allowing you to switch effortlessly between red and green.

    • category
    • environment
    • voltage
    spec →
  • Legion LightingEXIT SIGN - SERIES EXHLWLpartial

    HAZARDOUS LOCATION POLYCARBONATE BUY AMERICA OPTION Red or green letters. Single or double face available. Grey housing color. Field selectable knockout chevron directional indicators. Options include self diagnostics and tamperproof hardware. IP66. Rated for Class 1, Division 2, Groups A, B, C and D.

    • category
    • environment
    • voltage
    spec →

Cross-references are informational starting points — verify with the manufacturer before specifying or purchasing. Spot a bad match? Report it →